Hardware Installation — 15
2.4.3. Joining instruction
• All ECP/EUP products are pre-joined with the same network password (“HomePlugAV”) as the factory default
mode to support plug & play configuration between ECP/EUP Series.
• If the receiving switch and all of ECP/EUP-Transmitters are already Joined (Join LED on both devices), It is
unnecessary to join the devices again pressing JOIN button.
• ECP/EUP-28XXRM series have 2 or 4 network groups with every 4 channels (1-4, 5-8, 9-12, 13-16) and It is
possible to avoid network interference by setting the password of each group.
Group A
Group B
Group C
Group D
1.
Basic connection
Prepare 4 short coaxial cables for convenience and connect each ECP/EUP-Transmitters to
Group A (B-Linx port 1 to 4) and apply the power to the receiving switch.
2.
Unjoin (If required
, when Join LED on both receiving switch and ECP-Transmitter is not ON)
Removing the password
A. Push the join button for 15 seconds on each unit of ECP/EUP-Transmitter in Group A.
B. ECP/EUP-Transmitter will reboot and it is ready to be joined.
C. BNC Join LED turns off.
3.
Join :
We recommend using the Intercoax Manager Software to join the devices (the software can be downloaded on
our website)
Creating new password (Random password)
A. After unjoining, press the Group A join button and hold for 2 seconds and release the button.
B. Press the join button on one of ECP/EUP-Transmitters and hold for 2 seconds and release the button. PWR
LED turns off and on, and then BNC Join LED turns on and will be flickering and it means both devices are
joined successfully.
C. Join other 3 units of ECP/EUP-Transmitters repeating above steps (A, B)