Hardware Installation — 6
No.
Description
3
Smart B-Linx / T-Linx Detection On
Off :
B–Linx / T-Linx Detection mode On/Off switch
-
Detection Mode ON:
Detects B-Linx & T-Linx devices before supplying power over Coax.
-
Detection mode OFF:
By-pass detection, classification and power management checks.
[Caution]
Do not connect analog cameras or network devices on BNC or RJ-45 port directly if Smart
B-Linx / T-Linx detection switch is OFF, it may cause a serious damage to the device connected.
4
Join (1-4, 5-8, 9-12, 13-16) :
Hidden button to create new Network group with ECP Transmitters.
- Press the button with a paper clip and hold for 2 seconds for Joining (Create new password).
- Press the button with a paper clip and hold for 15 seconds for Unjoining
(Remove the existing password).
[Note]
Please refer to the Network Grouping Software manual, available on Intercoax' Website.
5
Buzzer On
Off :
Move the switch left or right to buzzer sound on or off.
6
Factory Reset :
The hidden factory reset button.
Press and hold for 10 seconds the reset button to restore to its original factory settings.
7
SFP :
Connect an SFP module for uplink data (1000 Base-FX GBIC slot).
8
Link :
Connect an RJ45 Ethernet cable for uplink data (10/100/1000 BaseT).
2.2. Rear Panel
2
1
No.
Description
1
Power ON/OFF Switch
2
Power Connector
The connector is for 100~240V AC power inputs 50Hz/60Hz