background image

16 Ga. Medium Crown Stapler 

Drives 7/16" Crown Staples (1" to 2" / 25 to 51mm)

Model No. SN5016 

Item No. 64405

13

Interchange Brands  

Operator’s Manual

When loading staples into Stapler

 

Do not pull trigger

 

Do not depress safety/push lever

 

Keep stapler pointed downward

1 . 

Pull the staple feeder backward and 

attach it securely to a groove of the 

magazine .

2 . 

Place the staple strip over the 

magazine . Make sure that the staple 

strip slides freely on the magazine .

3 . 

Pull the staple feeder backward . 

The, detach it from the groove 

of magazine and softly bring the 

staple back as if it were being gently 

pushed, avoiding any impact .

4 . 

The stapler is now ready to operate .

Staple Loading

!

 WARNING 

NEVER connect stapler to pressure which potentially 

exceeds 150psi.
NEVER USE NON-RELIEVING COUPLER ON STAPLER. 

The stapler and air hose must have a hose coupler so that 

all pressure is removed from the stapler when the coupler is 

disconnected . The connector on the tool must not hold pressure 

when the air supply is disconnected . If the wrong fitting is 

used, the tool can remain charged with air after disconnecting 

and thus will be able to drive a staple even after the air line is 

disconnected, possibly causing injury .

DANGER

NEVER use oxygen or other bottled gases, as an 

explosion may occur.

!

!

 CAUTION

If the staple feeder is suddenly 

released, it can return abruptly, 

causing deformation and/or scatter, 

eventually ending up in clogged 

staples. 
Be sure to bring back the staple 

feeder, avoiding any impact.

Summary of Contents for SN5016

Page 1: ...Carefully read through this OPERATOR S MANUAL to ensure efficient safe operation It is recommended that the MANUAL be kept readily available as an important refer ence when using this tool Medium Crow...

Page 2: ...ation 5 Accessories 5 Safety Information Safety Instructions 6 9 Employer s Responsibilities 9 Operating the Stapler Air Supply Connections Operating Pressure 10 11 Lubrication 11 Directional Exhaust...

Page 3: ...Y Most accidents that result from the operation and maintenance of staplers are caused by the failure to observe basic safety rules or precautions An accident can often be avoided by recognizing a pot...

Page 4: ...ded Operating Pressure 70 to 120 psi 5 to 8 5 kgs Applications Wall Sheathing Subflooring Roof Decking Furniture Frames Crate and Box Assembly and Vinyl Siding Staple Specifications FASTENERS 16 ga 06...

Page 5: ...Medium Crown Stapler Drives 7 16 Crown Staples 1 to 2 25 to 51mm Model No SN5016 Item No 64405 5 Interchange Brands Operator s Manual Accessories STANDARD ACCESSORIES Parts Identification 1 Eye Protec...

Page 6: ...rs from loud noise Wear head protection to protect your head from flying objects 3 KEEP FACE HANDS AND FEET AWAY FROM FIRING HEAD AT ALL TIMES Never place your face hands or feet near the firing head...

Page 7: ...pler appears to be operating unusually is making strange noises has parts missing or appears to be defective stop using it immediately and arrange for repairs by an authorized service center 15 CHECK...

Page 8: ...FUL OF DOUBLE FIRING DUE TO RECOIL If the safety push lever is unintentionally allowed to re contact the work piece following recoil an unwanted fastener will be driven In order to avoid this undesira...

Page 9: ...o tool malfunction and resulting injuries Only authorized service personnel should repair the stapler 32 NEVER MODIFY OR ALTER A STAPLER Doing so may cause it to malfunction and personal injuries may...

Page 10: ...19 3 Safety Standard for Compressors for Process Industries Moisture or oil in the air compressor may accelerate wear and corrosion in the stapler Drain daily Connections 1 Fittings Install a female...

Page 11: ...a higher than required air pressure unnecessarily over stresses the stapler Do not exceed this recommended operating pressure Lubrication It is important that the tool be properly lubricated Without...

Page 12: ...h the safety push lever and does not operate unless the safety push lever is depressed upward position There are two methods of operation to drive staples with this Stapler Single Fire The switch loca...

Page 13: ...dy to operate Staple Loading WARNING NEVER connect stapler to pressure which potentially exceeds 150psi NEVER USE NON RELIEVING COUPLER ON STAPLER The stapler and air hose must have a hose coupler so...

Page 14: ...e air pressure to 70psi Connect the air hose Do not load any staples in the stapler THE STAPLER MUST NOT LEAK AIR Hold the stapler downward and pull the trigger THE STAPLER MUST NOT LEAK AIR 3 Remove...

Page 15: ...damaged Piston O ring worn or damaged Replace with Genuine staples Replace staple feeder Replace ribbon spring Replace O ring Staples jam driven staple is bent Check for proper staples Driver blade w...

Page 16: ...performed Drain air line filter daily Keep lubricator filled Clean filter element then blow air through filter in direction opposite to normal flow Clean magazine and feeder mechanism Keep safety pus...

Page 17: ...Crown Stapler Drives 7 16 Crown Staples 1 to 2 25 to 51mm Model No SN5016 Item No 64405 17 Interchange Brands Operator s Manual PARTS DRAWING SCHEMATICS FOR SN5016 Parts Drawing Schematics Parts List...

Page 18: ...3X15 20 321920 DRIVER BLADE Loctite 262 69 320880 CONTACT PLATE 21 310370 PISTON 70 620370 SPRING 22 510510 O RING 37 5X3 55 71 110190 ADJUST BUTTOM 23 310180 CYLINDER 72 640010 ROLL PIN 2X8 24 520130...

Page 19: ...SN5016 98516 SN5016K7 Kit 7 Safety Kit for SN5016 98517 SN5016K8 Kit 8 Feeder Kit for SN5016 WARNING Always follow the tool manufacturer s safety and maintenance instructions Always wear safety glass...

Page 20: ...this war ranty 4 Labor charges maintenance or loss damage and repairs resulting from im proper operation are not covered by this warranty GENERAL WARRANTY CONDITIONS This warranty will be honored only...

Reviews: