background image

16 Ga. Medium Crown Stapler 

Drives 7/16" Crown Staples (1" to 2" / 25 to 51mm)

Model No. SN5016 

Item No. 64405

14

Interchange Brands  

Operator’s Manual

Testing The Stapler

Before using the stapler, test it by using the check list below . Conduct the test in 

the following order . If abnormal tests occur, stop using the stapler and contact an 

authorized service center immediately .

 

1 . 

Disconnect air hose from stapler .
Remove all staples from stapler .

ALL SCREWS MUST BE TIGHTENED.
If any screws are loose, tighten them .
THE SAFETY/PUSH LEVER AND  

TRIGGER MUST MOVE SMOOTHLY.

2 . 

Adjust the air pressure to 70psi .
Connect the air hose .
Do not load any staples in the 

stapler .

THE STAPLER MUST NOT LEAK AIR.

Hold the stapler downward and pull 

the trigger .

THE STAPLER MUST NOT LEAK AIR.

3 . 

Remove the finger from the trigger 

and press the safety/push lever 

against the wood .

THE STAPLER MUST NOT OPERATE.

4 . 

Without touching the trigger, depress 

the safety/push lever against the 

work piece .

 

„

Pull the trigger .

THE STAPLER MUST OPERATE.

5 . 

With the stapler off of the work 

piece, pull the trigger . Depress the 

push lever against the work piece .

THE STAPLER MUST OPERATE.

6 . 

If no abnormal operation is 

observed, you may load staples in 

the stapler . 
Drive staples into a test piece that 

is the same type to be used in the 

actual application .

THE STAPLER MUST OPERATE 

PROPERLY.

Summary of Contents for SN5016

Page 1: ...Carefully read through this OPERATOR S MANUAL to ensure efficient safe operation It is recommended that the MANUAL be kept readily available as an important refer ence when using this tool Medium Crow...

Page 2: ...ation 5 Accessories 5 Safety Information Safety Instructions 6 9 Employer s Responsibilities 9 Operating the Stapler Air Supply Connections Operating Pressure 10 11 Lubrication 11 Directional Exhaust...

Page 3: ...Y Most accidents that result from the operation and maintenance of staplers are caused by the failure to observe basic safety rules or precautions An accident can often be avoided by recognizing a pot...

Page 4: ...ded Operating Pressure 70 to 120 psi 5 to 8 5 kgs Applications Wall Sheathing Subflooring Roof Decking Furniture Frames Crate and Box Assembly and Vinyl Siding Staple Specifications FASTENERS 16 ga 06...

Page 5: ...Medium Crown Stapler Drives 7 16 Crown Staples 1 to 2 25 to 51mm Model No SN5016 Item No 64405 5 Interchange Brands Operator s Manual Accessories STANDARD ACCESSORIES Parts Identification 1 Eye Protec...

Page 6: ...rs from loud noise Wear head protection to protect your head from flying objects 3 KEEP FACE HANDS AND FEET AWAY FROM FIRING HEAD AT ALL TIMES Never place your face hands or feet near the firing head...

Page 7: ...pler appears to be operating unusually is making strange noises has parts missing or appears to be defective stop using it immediately and arrange for repairs by an authorized service center 15 CHECK...

Page 8: ...FUL OF DOUBLE FIRING DUE TO RECOIL If the safety push lever is unintentionally allowed to re contact the work piece following recoil an unwanted fastener will be driven In order to avoid this undesira...

Page 9: ...o tool malfunction and resulting injuries Only authorized service personnel should repair the stapler 32 NEVER MODIFY OR ALTER A STAPLER Doing so may cause it to malfunction and personal injuries may...

Page 10: ...19 3 Safety Standard for Compressors for Process Industries Moisture or oil in the air compressor may accelerate wear and corrosion in the stapler Drain daily Connections 1 Fittings Install a female...

Page 11: ...a higher than required air pressure unnecessarily over stresses the stapler Do not exceed this recommended operating pressure Lubrication It is important that the tool be properly lubricated Without...

Page 12: ...h the safety push lever and does not operate unless the safety push lever is depressed upward position There are two methods of operation to drive staples with this Stapler Single Fire The switch loca...

Page 13: ...dy to operate Staple Loading WARNING NEVER connect stapler to pressure which potentially exceeds 150psi NEVER USE NON RELIEVING COUPLER ON STAPLER The stapler and air hose must have a hose coupler so...

Page 14: ...e air pressure to 70psi Connect the air hose Do not load any staples in the stapler THE STAPLER MUST NOT LEAK AIR Hold the stapler downward and pull the trigger THE STAPLER MUST NOT LEAK AIR 3 Remove...

Page 15: ...damaged Piston O ring worn or damaged Replace with Genuine staples Replace staple feeder Replace ribbon spring Replace O ring Staples jam driven staple is bent Check for proper staples Driver blade w...

Page 16: ...performed Drain air line filter daily Keep lubricator filled Clean filter element then blow air through filter in direction opposite to normal flow Clean magazine and feeder mechanism Keep safety pus...

Page 17: ...Crown Stapler Drives 7 16 Crown Staples 1 to 2 25 to 51mm Model No SN5016 Item No 64405 17 Interchange Brands Operator s Manual PARTS DRAWING SCHEMATICS FOR SN5016 Parts Drawing Schematics Parts List...

Page 18: ...3X15 20 321920 DRIVER BLADE Loctite 262 69 320880 CONTACT PLATE 21 310370 PISTON 70 620370 SPRING 22 510510 O RING 37 5X3 55 71 110190 ADJUST BUTTOM 23 310180 CYLINDER 72 640010 ROLL PIN 2X8 24 520130...

Page 19: ...SN5016 98516 SN5016K7 Kit 7 Safety Kit for SN5016 98517 SN5016K8 Kit 8 Feeder Kit for SN5016 WARNING Always follow the tool manufacturer s safety and maintenance instructions Always wear safety glass...

Page 20: ...this war ranty 4 Labor charges maintenance or loss damage and repairs resulting from im proper operation are not covered by this warranty GENERAL WARRANTY CONDITIONS This warranty will be honored only...

Reviews: