16 Ga. Wide Crown Stapler 

Drives 15/16" Crown Staples (5/8" to 2" / 16 to 50mm)

Model No. SGSW5016 

Item No. 64415

7

Interchange Brands  

Operator’s Manual

10. 

STAY ALERT. 

Watch what you are doing . Use common sense and do not operate the stapler when 

you are tired . The stapler should never be used if you are under the influence of 

alcohol, drugs or medication that makes you drowsy .

11. 

KEEp WORK AREA CLEAN. 

Cluttered areas invite injuries . Clear all work areas of unnecessary tools, debris, etc .

12. 

NEVER CARRY THE STApLER BY THE HOSE.

13. 

HANDLE THE STApLER CAREFULLY.
This stapler was designed for driving staples into wood and similar items . Operate the 

stapler safely and correctly and do not use for purposes other than those specified in 

this manual . 
Because of high air pressure in the stapler, cracks in the surface are dangerous . To 

avoid tool damage, do not drop the stapler or strike the stapler against hard surfaces 

and do not scratch or engrave on the stapler . Handle the stapler carefully .

14. 

BEFORE USING THE STApLER, CHECK TO MAKE SURE pARTS ARE NOT 

BROKEN OR MISSING AND THAT ALL SCREWS ARE TIGHT. DO NOT 

OpERATE A TOOL THAT IS OpERATING ABNORMALLY. 

If the stapler appears to be operating unusually, is making strange noises, has parts 

missing or appears to be defective, stop using it immediately and arrange for repairs 

by an authorized service center .

15. 

CHECK SAFETY/pUSH LEVER BEFORE USE. 

Make sure the safety/push lever operates properly . Never use the stapler unless the 

safety/push lever is operating properly, otherwise the stapler could drive a fastener 

unexpectedly . Do not tamper with or remove the safety/push lever, otherwise the 

safety/push lever becomes inoperable .

16. 

CHOICE OF TRIGGER METHOD IS IMpORTANT.
Read and understand section titled “Methods of Operation .”

17. 

DO NOT USE OXYGEN, COMBUSTIBLE OR OTHER BOTTLED GASES. 

EXpLOSION MAY OCCUR.
Never use oxygen, combustible gases or any other bottled gases as a power source 

for the stapler . Use of these gases is dangerous, as the stapler will explode .
Use only clean, dry, regulated compressed air as a power source .

18. 

DO NOT EXCEED 120 psi.
Do not exceed maximum recommended air pressure 120 psi . Never connect the 

stapler to pressure which potentially exceeds 150 psi as the stapler can burst .

19. 

NEVER USE IN pRESENCE OF FLAMMABLE LIQUIDS OR COMBUSTIBLES. 

The stapler produces sparks during operation . Never use the stapler on sites 

containing lacquer, paint, benzine, thinner, gasoline, gases, adhesive agents or other 

materials which are combustible or explosive .

20. 

KEEp ALL SCREWS AND COVERS MOUNTED TIGHTLY IN pLACE. 

Keep all screws and covers tightly mounted . Check their condition periodically . Never 

use the stapler if parts are missing or damaged .

21. 

DO NOT USE THE WRONG FITTING ON STApLER . 
The stapler and air hose must have a hose coupler so that all pressure is removed 

from the stapler when the coupler is disconnected . The connector on the stapler must 

not hold pressure when the air supply is disconnected . If the wrong fitting is used, the 

stapler can remain charged with air after disconnecting and thus will be able to drive a 

fastener even after the air line is disconnected, possibly causing injury .

Summary of Contents for SGSW5016

Page 1: ...fully read through this OPERATOR S MANUAL to ensure efficient safe operation It is rec ommended that the MANUAL be kept readily available as an important reference when using this tool Ask for Genuine...

Page 2: ...ation 5 Accessories 5 Safety Information Safety Instructions 6 9 Employer s Responsibilities 9 Operating the Stapler Staple Loading 10 Methods of Operation 10 Adjusting the Stapling Depth 11 Operation...

Page 3: ...URY Most accidents that result from the operation and maintenance of staplers are caused by the failure to observe basic safety rules or precautions An accident can often be avoided by recognizing a p...

Page 4: ...taple Length 5 8 to 2 16 to 50mm Recommended Operating Pressure 70 to 120 psi 5 to 8 5 kgs Applications Wire lathing Staple Specifications FASTENERS 16 ga 063 x 055 1 60 x 1 40mm 5 8 to 2 16 to 50mm 1...

Page 5: ...de Crown Stapler Drives 15 16 Crown Staples 5 8 to 2 16 to 50mm Model No SGSW5016 Item No 64415 5 Interchange Brands Operator s Manual Accessories STANDARD ACCESSORIES Parts Identification 1 Eye Prote...

Page 6: ...ars from loud noise Wear head protection to protect your head from flying objects 3 KEEP FACE HANDS AND FEET AWAY FROM FIRING HEAD AT ALL TIMES Never place your face hands or feet near the firing head...

Page 7: ...h lever is operating properly otherwise the stapler could drive a fastener unexpectedly Do not tamper with or remove the safety push lever otherwise the safety push lever becomes inoperable 16 CHOICE...

Page 8: ...the fastener could fly free and hit someone 27 NEVER DRIVE FASTENERS FROM BOTH SIDES OF A WALL AT THE SAME TIME The fasteners could be driven into and through the wall and hit a person on the opposite...

Page 9: ...to tool malfunction and resulting injuries Only authorized service personnel should repair the stapler 36 NEVER MODIFY OR ALTER A STAPLER Doing so may cause it to malfunction and personal injuries ma...

Page 10: ...could result in accidental firing of the tool 2 1 STAPLE LOADING Keep stapler pointed downward Pull the staple feeder backward until it latches Place the staple strip onto the rail of the magazine Mak...

Page 11: ...ool out of direct sunlight as excessive heat can deteriorate bumpers o rings and other rubber parts resulting in increased maintenance OPERATING THE TOOL DRIVING DEPTH ADJUSTMENT Depth drive adjustmen...

Page 12: ...ure is 70 to 120 psi 5 to 8 5 kgs Maximum permissible operating pressure is 120 psi Select the operating pressure within this range for the best fastener performance The fastener length and thickness...

Page 13: ...ir Keep the filter clean by maintaining tool regularly Drain daily Regulator The regulator controls the operating pressure for safe operation of the tool Inspect the regulator before operation to be s...

Page 14: ...2 Adjust the air pressure to 70 psi Connect the air hose Do not load any staples in the stapler THE STAPLER MUST NOT LEAK AIR Hold the stapler downward and pull the trigger THE STAPLER MUST NOT LEAK A...

Page 15: ...open blade guide 4 Remove the jammed staple with a slotted head screwdriver 5 Close blade guide and latch 6 In case of frequent jams contact an authorized service center A qualified person should per...

Page 16: ...eners jam in tool Solution Check for correct fastener Check proper air pressure Check magazine and feeder operation Replace piston driver assembly Problem Intermittent feed Solution Use recommended fa...

Page 17: ...arts Drawing Schematics Parts List Parts Kits 1 3 5 6 7 10 11 12 13 14 15 16 17 18 14 19 20 22 9 8 SGSW5016 2 4 14 21 23 27 34 35 36 38 39 40 26 3 30 31 32 33 29 42 44 55 53 52 51 49 50 70 69 75 85 84...

Page 18: ...X2 4 63 621440 SPRING 19 110570 CYLINDER RING 64 324040 STRAIGHT PIN 20 511630 O RING 47X2 4 65 420160 PIN CAP B 21 323990 WASHER 66 324300 NUT 22 410910 BUMPER 67 310880 COVER A 23 110580 BODY 68 640...

Page 19: ...98117 SGSW5016K7 Kit 7 Safety Kit for SGSW5016 98118 SGSW5016K8 Kit 8 Feeder Kit for SGSW5016 WARNING Always follow the tool manufacturer s safety and maintenance instructions Always wear safety glass...

Page 20: ...from this warranty 4 Labor charges maintenance or loss damage and repairs resulting from improper operation are not covered by this warranty This warranty will be honored only if 1 Clean dry regulate...