16 Ga. Wide Crown Stapler
Drives 15/16" Crown Staples (5/8" to 2" / 16 to 50mm)
Model No. SGSW5016
Item No. 64415
12
Interchange Brands
Operator’s Manual
AIR SUppLY
power source (Compressor)
Use only clean, dry, regulated compressed air as a
power source for this tool .
Never use oxygen or other bottled gases, as an
explosion may occur .
Air compressors used to supply compressed air to this
tool must comply with the requirements of the latest
version of ANSI Standard B 19 .3 Safety Standard for
Compressors for Process Industries .
Moisture or oil in the air compressor may accelerate
wear and corrosion in the tool .
Drain daily .
Never use a tool that is leaking air .
Disconnect tool from air supply and remove fasteners
from magazine before doing tool maintenance, clearing a
jammed fastener, or moving to another location .
OpERATING pRESSURE
Recommended operating pressure is 70 to 120 psi /
5 to 8 .5 kgs .
Maximum permissible operating pressure is 120 psi .
Select the operating pressure within this range for the
best fastener performance . The fastener length and
thickness and the hardness of the wood are factors in
determining what the pressure should be set at .
Do not exceed recommended operating pressure .
Moisture or oil in the air compressor may accelerate wear
and corrosion in the tool .
Drain daily .
OpERATING THE TOOL
LUBRICATION
It is important that the tool be properly lubricated .
Without proper lubrication, the tool will not work properly
and parts will wear prematurely .
Use INTERCHANGE pneumatic tool lubricant . Do not use
detergent oil or additives . These lubricants will harm the
O-rings and other rubber parts . This will cause the tool to
malfunction .
Filter-regulator-lubricator units should always be used .
Keep the lubricator filled with INTERCHANGE pneumatic
tool lubricant .
If a lubricator is not available, supply 3 to 5 drops of
INTERCHANGE pneumatic tool lubricant into the air plug
on the tool twice a day .