background image

15

o

 Coil Nailer

Drives Wire Collated Nails (2" to 3-9/16" / 50 to 90mm)

Model No. CN90-15

Item No. 65590

10

Interchange Brands  

Operator’s Manual

Operating the Nailer

NOtE: 

The information contained in this Manual is designed to assist you in the safe 

operation of the nailer . Some illustrations in this Manual may show details or attach-

ments that are different from those on your nailer .

Air Supply, Connections and Operating Pressure

Read section titled SAFETY. Make sure of the following before operation:

Air Supply

Power Source (Compressor)

 

„

Use only clean, dry, regulated compressed air as a power source for this 

nailer .

 

„

NEVER use oxygen or other bottled gases, as an explosion may occur .

 

„

Air compressors used to supply compressed air to this nailer must comply 

with the requirements of the latest version of ANSI Standard  

B 19 .3 Safety Standard for Compressors for Process Industries .

 

„

Moisture or oil in the air compressor may accelerate wear and corrosion in 

the nailer .

 

„

Drain daily .

Connections

1 . 

Fittings
Install a female coupler to the hose . The female coupler will connect to the quick 

release that fits the tool .

2 . 

Filter-Regulator-Lubricator

 

„

NEVER connect nailer to pressure which potentially exceeds 150 psi .

 

„

Filter-regulator-lubricator units supply an optimum condition for the nailer 

and extend the nailer life . These units should always be used .

Filter

 

„

The filter removes moisture and dirt mixed in compressed air .

 

„

Keep the filter clean by maintaining tool regularly .

 

„

Drain daily .

Regulator

 

„

The regulator controls the operating pressure for safe operation of the nailer .

 

„

 Inspect the regulator before operation to be sure it operates properly .

Lubricator

 

„

The lubricator supplies an oil mist to the nailer .

 

„

Inspect the lubricator before operation to be sure the supply of lubricant is 

adequate .

 

„

If an inline lubricator is not used, a few drops of oil will need to be added to 

the air inlet before each use .

Summary of Contents for 65590

Page 1: ...ol Carefully read through this OPERATOR S MANUAL to ensure efficient safe operation It is recommended that the MANUAL be kept readily available as an important refer ence when using this tool 15o Coil...

Page 2: ...4 Parts Identification 5 Accessories 5 Safety Information Safety Instructions 6 9 Employer s Responsibilities 9 Operating the Nailer Air Supply Connections Operating Pressure 10 11 Lubrication 11 Oper...

Page 3: ...could result in DEATH or SERIOUS INJURY Most accidents that result from the operation and maintenance of nailers are caused by the failure to observe basic safety rules or precautions An accident can...

Page 4: ...ty 225 to 275 Nails Recommended Operating Pressure 70 to 120 psi 5 to 8 5 kgs Applications Assembly and Repair of Pallets Drums Export Wooden Boxes and Wooden Fencing General Construction Applications...

Page 5: ...Exhaust Cover TOOL AIR FITTINGS This tool uses a minimum 1 4 N P T male plug The inside diameter should be 0 28 7mm or larger The fitting must be capable of discharging tool air pressure when disconn...

Page 6: ...ars from loud noise Wear head protection to protect your head from flying objects 3 KEEP FACE HANDS AND FEET AWAY FROM FIRING HEAD AT ALL TIMES Never place your face hands or feet near the firing head...

Page 7: ...6 BEFORE STARTING WORK CHECK TO SEE IF YOUR TOOL HAS A FASTENING OPERATION SWITCHING DEVICE Not available on all tool models If this nailer includes a fastening operation switching device check the se...

Page 8: ...S Air hoses should be professional grade and have a minimum of 150 psi working pressure Make sure that the hose is securely fastened If there is any damage to the hose replace it before using the nail...

Page 9: ...PARTS ACCESSORIES OR FASTENERS Unauthorized parts accessories or fasteners may void your warranty and can lead to tool malfunction and resulting injuries Only authorized service personnel should repai...

Page 10: ...sors for Process Industries Moisture or oil in the air compressor may accelerate wear and corrosion in the nailer Drain daily Connections 1 Fittings Install a female coupler to the hose The female cou...

Page 11: ...ating pressure is 150 psi Select the operating pressure within this range for the best fastener performance The nail length and thickness and the hardness of the wood are factors in determining what t...

Page 12: ...m work piece and pull the trigger The tool must not operate 9 Disconnect the air supply OPERATION Danger to the eyes exists due to the possibility of flying fasteners and debris when operating the nai...

Page 13: ...ngs To change setting pull up on the post and twist to the correct step The nail support should be adjusted correctly to the position indicated in inches and millimeters inside magazine 3 Nail loading...

Page 14: ...e work piece The tool must fire the fastener 4 Adjust the air pressure to the lowest setting possible according to the diameters and length of fastener and the hardness of work piece WARNING Always fo...

Page 15: ...lubrication Apply air tool lubricant Nails jam in tool Bent nails Replace with new nails Broken or chipped driver Replace piston driver assembly bumper Wrong size nail Replace with correct type of na...

Page 16: ...2 Remove all nails 3 Remove the jammed nail with a slotted head screwdriver 4 In case of frequent jams contact an authorized service center A qualified person should perform repairs and maintenance P...

Page 17: ...rawing Schematics Parts List Parts Kits 1 2 4 5 3 6 8 9 10 11 13 7 12 16 15 18 20 21 23 24 25 26 19 22 57 68 75 82 79 81 70 69 65 63 66 64 62 60 61 59 74 27 80 76 78 77 71 29 27 28 40 53 39 43 36 35 3...

Page 18: ...110 Cylinder Seal 75 410140 Handle Grip 23 420340 Cylinder Ring 76 320570 Trigger 24 510960 O ring 90X3 05 77 320560 Contact Plate 25 410130 Bumper A 78 640110 Roll Pin 3X16 26 410120 Bumper B 79 4201...

Page 19: ...Kit for CN90 15 98639 CN90K9 Kit 9 Bumper Kit for CN90 15 Additional part in Kit 1 Order No 510990 O Ring 55X3 1 WARNING Always follow the tool manufacturer s safety and maintenance instructions Alwa...

Page 20: ...ranty 4 Labor charges maintenance or loss damage and repairs resulting from im proper operation are not covered by this warranty GENERAL WARRANTY CONDITIONS This warranty will be honored only if 1 Cle...

Reviews: