background image

8. Annex 
— 
 

 

Scape

 X® 

Technical specifications are  

sx65-006 

to change without notice.  

Operating manual 

Version 1.7 – Status: 04/2020 

Page 20 of 27 

poc: SFi 

8.2.2.

 

Top view 

 

 

Summary of Contents for Scape X sx65-006

Page 1: ...Scape X sx65 006 Operating manual ...

Page 2: ...____________________________________________________________________________13 4 4 Connection to the network __________________________________________________________________________________________13 5 Switching on ______________________________________________________________________________________________________14 6 Display settings OSD _______________________________________________________...

Page 3: ...ay cause undesired operation This Class A digital apparatus complies with Canadian ICES 003 This manual is applicable for the following device Scape X 65 sx65 006 Information in this document is subject to change without notice 2020 Interactive Scape GmbH All rights reserved The document or excerpts from the document may not be duplicated without the prior permission of Interactive Scape GmbH Inte...

Page 4: ...using power strips and extension cords if possible Do not chain multiple extension cords or power strips together Overheating Heat build up can overheat the screen This can damage the device Ensure there is sufficient air circulation around the Scape X Make sure all the ventilation holes on around the screen are uncovered Excess voltage from lightning strikes In the event of a thunderstorm there i...

Page 5: ... doctor or the manufacturer of your medical device pacemaker hearing aid implant with electronic control etc to see if it can work your Scape X without interference If necessary maintain the minimum distance of 15 cm recommended by medical device manufacturers to avoid interference with your medical device Hazardous environments Under unfavorable conditions radio waves near explosive atmospheres m...

Page 6: ...vertheless it is recommended to clean the glass surface of the screen regularly Disconnect the device from the mains before cleaning Typically a solution of isopropyl alcohol and water 50 50 blend ratio or the included screen cleaning kit are best for cleaning the touch sensor Apply the solution to a soft lint free cloth Avoid using rough cloths Use the cloth to clean the glass surface Apply the l...

Page 7: ... 1 IR Sensor for remote control 2 Switch between Touch TUIO USB Touch 3 RJ 45 Lan interface to use the Touch Object Assistant 4 USB Connection Type B for direct connection of touch and PC 5 DisplayPort input 6 HDMI 2 0 input UHD 60 Hz 7 HDMI input 8 DVI input 9 Stand by 17 10 Status LED 11 Close OSD back show input selection 21 12 Plus Right 23 13 Minus Left 22 14 Open OSD confirm selection 20 15 ...

Page 8: ... 8 of 27 poc SFi 2 2 Remote control analogous to buttons on the screen All keys on the remote control which are not explained above are not required for operation of Scape X and do not have any function 17 Stand by 9 18 Display mode selection 19 Show input selection 20 Show OSD confirm selection 14 21 Close OSD 11 22 Left Minus 13 23 Right Plus 12 ...

Page 9: ...and insert the supplied screw covers The Scape X may only be operated at a tilt angle of 0 90 Scape X 65 For horizontal mounting 0 tilt angle the screen must be supported at least at its 4 corners Ideally the frame is supported along its entire circumference The Scape X comes with VESA compatible threaded holes The monitor can be mounted in a landscape format by using these holes For mounting with...

Page 10: ... normal conditions In adverse environments such as high temperature polluted air or high humidity special precautions should be taken that are not covered in this document For ventilation the Scape X has 6 fans on the rear 3 for taking air in and 3 for blowing air out Both inlet and outlet sides move 0 5 m air min Front Underside front above __________________________________________________ blue ...

Page 11: ...n to prevent the cold air from warming up 4 The intake opening of the enclosure 2 should measure at least the sum of the air intake openings of all the installed devices Scape Tangible Silent PC min 200 cm The exhaust opening 6 should also be adjusted accordingly Circular or square openings are more suitable than narrow openings o Scape X min 150 cm o Scape X Silent PC min 200 cm If the intake and...

Page 12: ... your ventilation system Any operation of the devices above the recommended range will shorten their service life Functional impairment or hardware failure due to overheating of the systems are not covered by the warranty obligation of Interactive Scape GmbH 3 1 3 Housing with additional heat sources The ventilation instructions in this document refer exclusively to hardware provided by Interactiv...

Page 13: ...atically To use your Scape X as a pure USB HID touch input device connect the USB port on the underside of the Scape X see chapter 2 1 Connections Controls Point 4 directly to your application PC Set the switch for the touch signal to Touch USB see chapter 2 1 Connections and controls point 2 With this method the Scape X AI Recognition Unit cannot be used 4 4 Connection to the network The Scape X ...

Page 14: ...vice is switched on Do not touch the touch screen during device startup otherwise there will be errors in the touch and object detection The device will take about 1 5 hours to power up before it reaches its final operating temperature During this time the touch sensor of the device constantly adapts to its environment This has a direct effect on long term object recognition If your application re...

Page 15: ...values for each setting or to select the appropriate option The Menu 20 button activates the selected option and returns to the last selection level The Exit 21 button resets the setting to its original value and returns to the next higher menu level or closes the OSD when you are at the top menu level The OSD automatically shuts off after a few seconds of inactivity Menu opened select menu item M...

Page 16: ...mbH Wilhelmine Gemberg Weg 6 10179 Berlin 49 0 30 698 094 150 7 2 Problems and solutions Error Possible cause Possible solution No picture is shown even though the PC is turned on The DisplayPort or HDMI cable has come loose Check the connection of cable with the PC Plug the cable into another connector on the PC The screen is switched to the wrong input Set the input correctly see chapter 6 Displ...

Page 17: ... lifetime 60 000 h Pixel class ISO 9241 307 Pixel Error Class II Operational period 24 7 Max ambient humidity Operation 10 90 not condensing Max ambient humidity Storage 10 90 not condensing Max ambient temperature Operation 0 35 C 32 95 F Max ambient humidity Storage 20 60 C 4 140 F Dimensions W x H x D 1521 5 x 896 4 x 94 mm Weight 72 kg Mounting VESA 400x400 mm 600x400 mm 800x400 mm Max tipping...

Page 18: ...erfaces Touch HID USB TUIO 1 1 2 0 Video 1x HDMI 1 4 1x HDMI 2 0 1x DisplayPort Electrical specifications Operating voltage 100 240 VAC Power draw 245 W Certifications CE certified RoHS compliant 8 1 2 Recognition Unit Technology Scape X AI Recognition Unit Compatible with Scape X Tags Shape Capore Basic Shape Shape Large Plus Magnify Magnify Large ...

Page 19: ...8 Annex Scape X Technical specifications are sx65 006 to change without notice Operating manual Version 1 7 Status 04 2020 Page 19 of 27 poc SFi 8 2 Technical Drawings 8 2 1 Perspective ...

Page 20: ...8 Annex Scape X Technical specifications are sx65 006 to change without notice Operating manual Version 1 7 Status 04 2020 Page 20 of 27 poc SFi 8 2 2 Top view ...

Page 21: ...8 Annex Scape X Technical specifications are sx65 006 to change without notice Operating manual Version 1 7 Status 04 2020 Page 21 of 27 poc SFi 8 2 3 Bottom view ...

Page 22: ...8 Annex Scape X Technical specifications are sx65 006 to change without notice Operating manual Version 1 7 Status 04 2020 Page 22 of 27 poc SFi ...

Page 23: ...8 Annex Scape X Technical specifications are sx65 006 to change without notice Operating manual Version 1 7 Status 04 2020 Page 23 of 27 poc SFi 8 2 4 Front view ...

Page 24: ...8 Annex Scape X Technical specifications are sx65 006 to change without notice Operating manual Version 1 7 Status 04 2020 Page 24 of 27 poc SFi 8 2 5 Right view ...

Page 25: ...8 Annex Scape X Technical specifications are sx65 006 to change without notice Operating manual Version 1 7 Status 04 2020 Page 25 of 27 poc SFi 8 2 6 Detail A Power connection ...

Page 26: ...8 Annex Scape X Technical specifications are sx65 006 to change without notice Operating manual Version 1 7 Status 04 2020 Page 26 of 27 poc SFi 8 2 7 Detail B Media connections ...

Page 27: ...Interactive Scape GmbH Wilhelmine Gemberg Weg 6 D 10179 Berlin T 49 30 69 809 41 00 F 49 30 69 809 429 www interactive scape com info interactive scape com ...