SC-9216R
SPEAKER LINE CHECKER
Tests
Tests
- AUTOMATIC TESTS
This is the type of test described in the Initial Operation and Routine Operation portions of this manual.
An internal timer has been set to conducts tests automatically at intervals ranging from 1 minute to 24 hours.
- MANUAL TESTS
Tests may be conducted manually, thus temporarily overriding the timer (automatic) setting. This allows a test to
be conducted at will without waiting for the next test interval or having to change the timer setting. To manually
conduct a test, depress the Op Mode button several times as needed until the “Single Check” or “All Check”
menu appears in the display, then depress ENTER. Automatic operation will resume after the manual test has
been completed.
- FAILURE CRITERIA
Ground Fault..........................................................................................Ground fault condition
Line Open ....................................................................................... > 125% of reference value
Line Impedance High...............................................................115% to 125% of reference value
Line Impedance Normal ................................................................85%-115% of reference value
Line Impedance Low....................................................................75% to 85% of reference value
Line Short ...........................................................................................< 75% of reference value
- REMOTE CAPABILITIES
Remote interrupt (EXT. IN)
The SC-9216R includes a provision for contact closure at a remote location to pause operation. Normal
operation resumes when the contact closure is released.
Remote fault indicator (FAULT OUT 1,2)
The SC-9216R includes a provision for a fault indicator at a remote location. Remote fault indicators are not
provided by Inter-M and must be custom designed and fabricated for the particular requirements of each
particular application. A block diagram of basic system elements is provided to assist in the design of a remote
fault indicator though this assistance will not be sufficient for every need.
Remote check indicator (CHECK OUT)
The SC-9216R includes a provision for a remote check indicator at a remote location. Remote check indicators
are not provided by Inter-M and must be custom designed and fabricated for the particular requirements of each
particular application. A block diagram of basic system elements is provided to assist in the design of a remote
check indicator though this assistance will not be sufficient for every need.