background image

PublIc Address MIxIng AMPlIfIer

7

PM-236/248/260

Rear Panel

Rear Panel

1. AC InPUt

It is a terminal to supply power to this device. The power used for this is PM-236 : Ac 120V or Ac 220-
240V, 50/60Hz, PM-248/260 : Ac 120-240V, 50/60Hz. do not bend by force, pull, twist, heat, or cut
the power cord. It may cause a fire or electric shock by damaging the cord.

2. IMPEDAnCE SElECtIOn SWItCh

It is a switch to select the impedance before connecting the speaker. select the impedance to use among 4Ω,
70V, 100V.

3. tEl In InPUt tERMInAl

It  is  a  terminal  to  use  by  connecting  with  the  telephone  exchange.  You  can  broadcast  directly  with  the
transmitter of phone.

When a signal is input to the Tel In input terminal, all other input signals will be lower as set by the Tel
In priority adjustment volume and the priority adjustment volume.

do not connect directly to the telephone network. (not connected to TnV-3 circuit)

4. tEl In VOlUME COntROllER

It is a controller to control the volume of Tel In input. If you set the volume to minimum, a signal of 0dbV
(1Vrms) can be input sensitivity; if you set the volume to maximum, a signal of -20dbV (100mVrms) can be
input sensitivity.

5. tEl In PRIORIty COntROl VOlUME (tEl In MUtE)

This is a volume that adjusts the volume of InPuT 1~2, cHIMe, and sIren sound when a signal is input to
the  Tel  In.  by  using  Tel  In  priority  adjustment  volume,  user  can  adjust  the  input  signal  to  InPuT  1~2,
cHIMe, and sIren. by using priority adjustment volume of InPuT 1~2, user can adjust the volume of InPuT
3~6, exT In.

1

4

3

2

5

6

8

9

7

10

11

12

13

14

Summary of Contents for PM-236

Page 1: ...Operation Manual Public Address Mixing Amplifier PM 236 248 260...

Page 2: ...onnect the power supply cord plug from the AC receptacle The mains plug of the power supply cord shall remain readily accessible CAUTION These servicing instructions are for use by qualified service p...

Page 3: ...tallation environment 2 Important safety Instructions 2 Overview 3 Features 3 Contents and Accessories 4 Operation 4 Front Panel 5 Rear Panel 7 Applications 11 Block Diagram 12 Specifications 14 Servi...

Page 4: ...ers stoves or other apparatus including amplifiers that produce heat 9 do not defeat the safety purpose of the polarized or grounding type plug A polarized plug has two blades with one wider than the...

Page 5: ...like hospitals restaurants and schools Features Features ClASS D AMPlIFIERS hAVIng 360W 480W 600W OF OUtPUt PM 236 360W PM 248 480W PM 260 600W hIgh Z 100V 70V AnD lOW Z 4 MUltIPlE InPUtS thREE MICS...

Page 6: ...tage before you plug into the power cord PM 236 Ac 120V or Ac 220 240V 50 60Hz PM 248 260 Ac 120 240V 50 60Hz 4 Please push the power switch then the power input led is on and the unit will be operate...

Page 7: ...ss and hold the button for more than 2 seconds to rewind 4 button Press the button briefly to move to the next audio file Press and hold the button for more than 2 seconds to fast forward 5 rePeAT but...

Page 8: ...he volume increases 9 SPEAKER SElECtIOn SWItCh It is a switch to turn On Off the signals printing with five speaker output terminals or to turn On Off whole output signals with an All switch In the ev...

Page 9: ...Tel In input terminal all other input signals will be lower as set by the Tel In priority adjustment volume and the priority adjustment volume do not connect directly to the telephone network not conn...

Page 10: ...he volume of InPuT 3 6 exT In sound when a signal is input to the InPuT 1 or InPuT 2 ex When press the switch of InPuT 2 and signal is input to InPuT 2 sound of InPuT 3 6 exT In is reduced 10 SPEAKER...

Page 11: ...output terminal to connect when recording the sound printed from this device or using other amps in parallel It is a balanced type and pin arrangements are g 13 PRIORIty COntROl VOlUME PRIORIty MUtE I...

Page 12: ...the connection of xlr jack euro Terminal and rcA jack Turn PHAnTOM switch Off if using the unbalanced cable 14 PRIORIty COntROl VOlUME PRIORIty MUtE This is a volume that adjust the volume of InPuT 3...

Page 13: ...PublIc Address MIxIng AMPlIfIer 11 PM 236 248 260 Applications Applications AMP SPK MIXER...

Page 14: ...VEL METER LED DRIVER 50 10 AMP MIC LINE Vph PHANTOM POWER AMP PHANTOM POWER Vph AMP Vph PHANTOM POWER TEMP SENS PROTECTION CIRCUIT 0dBV MIX OUT CHIME SIREN AC IN PWR SMPS 20 0 dBV TEL IN INPUT 1 60 20...

Page 15: ...50 10 AMP MIC LINE Vph PHANTOM POWER AMP PHANTOM POWER Vph AMP Vph PHANTOM POWER TEMP SENS PROTECTION CIRCUIT 0dBV MIX OUT CHIME SIREN PWR SMPS 20 0 dBV TEL IN INPUT 1 60 20dBV INPUT 2 60 20dBV INPUT...

Page 16: ...sensitivity Impedance MIc bAlAnce 60dbV 2k lIne bAlAnce 20dbV 2k rcA unbAlAnce 20dbV 20k 3 5 PHOne JAcK unbAlAnce 20dbV 2k Tel In bAlAnce 20 0dbV 40k exT In bAlAnce 0dbV 40k MIx OuT bAlAnce 0dbV THd...

Page 17: ...PublIc Address MIxIng AMPlIfIer 15 PM 236 248 260 DIMEnSIOnS 88 420 318 7 419...

Page 18: ...is available by contacting your warranty provider Variations and Options Variations and Options Variations Products supplied through legitimate sources are compatible with local Ac power requirements...

Page 19: ......

Page 20: ...ean company but rather a global company that is truly international in scope with factories and offices in Korea and china and sales and marketing operations located in Japan europe and the u s A With...

Reviews: