background image

PublIc Address MIxIng AMPlIfIer

5

PM-236/248/260

Front Panel

Front Panel 

1. USB SlOt

Please use your own with adjustment the volume using each input volume and master volume, the tone using
the tone control.

2. USB PlAy MODE SElECtIOn BUttOn

1)

■ 

button: Press the button to stop the audio file currently being played.

2)

|| button: Press the button to play or pause the audio file.

When led is turned on (by pressing the button once): current audio file is played.
When led blinks (by pressing the button twice): The audio file which is currently being played is paused.
3)

|◀◀

button:  Press  the  button  briefly  to  move  to  the  previous  audio  file.  Press  and  hold  the  button  for

more than 2 seconds to rewind.

4)

▶▶|

button: Press the button briefly to move to the next audio file. Press and hold the button for more

than 2 seconds to fast forward.

5) rePeAT button: Press the button to play the audio file repeatedly.

When led is turned off: All audio files are played repeatedly.

When led is turned on (by pressing the button once): Those files stored in the folder with currently
playing audio file are played repeatedly.

When  led  blinks  (by  pressing  the  button  twice):  Only  the  currently  playing  audio  file  is  played
repeatedly.

3. InPUt SIgnAl InDICAtOR

If there is an input signal to InPuT 1~6, due input signal indicator lights up.

1

2

3

14

12

11

13

4

5

6

8

7

9

10

support file systems

The maximum number of playable files

fAT16

512 files

fAT32

65535 files

nTfs

not supported

OuTPuT

5V     0.5A

Summary of Contents for PM-236

Page 1: ...Operation Manual Public Address Mixing Amplifier PM 236 248 260...

Page 2: ...onnect the power supply cord plug from the AC receptacle The mains plug of the power supply cord shall remain readily accessible CAUTION These servicing instructions are for use by qualified service p...

Page 3: ...tallation environment 2 Important safety Instructions 2 Overview 3 Features 3 Contents and Accessories 4 Operation 4 Front Panel 5 Rear Panel 7 Applications 11 Block Diagram 12 Specifications 14 Servi...

Page 4: ...ers stoves or other apparatus including amplifiers that produce heat 9 do not defeat the safety purpose of the polarized or grounding type plug A polarized plug has two blades with one wider than the...

Page 5: ...like hospitals restaurants and schools Features Features ClASS D AMPlIFIERS hAVIng 360W 480W 600W OF OUtPUt PM 236 360W PM 248 480W PM 260 600W hIgh Z 100V 70V AnD lOW Z 4 MUltIPlE InPUtS thREE MICS...

Page 6: ...tage before you plug into the power cord PM 236 Ac 120V or Ac 220 240V 50 60Hz PM 248 260 Ac 120 240V 50 60Hz 4 Please push the power switch then the power input led is on and the unit will be operate...

Page 7: ...ss and hold the button for more than 2 seconds to rewind 4 button Press the button briefly to move to the next audio file Press and hold the button for more than 2 seconds to fast forward 5 rePeAT but...

Page 8: ...he volume increases 9 SPEAKER SElECtIOn SWItCh It is a switch to turn On Off the signals printing with five speaker output terminals or to turn On Off whole output signals with an All switch In the ev...

Page 9: ...Tel In input terminal all other input signals will be lower as set by the Tel In priority adjustment volume and the priority adjustment volume do not connect directly to the telephone network not conn...

Page 10: ...he volume of InPuT 3 6 exT In sound when a signal is input to the InPuT 1 or InPuT 2 ex When press the switch of InPuT 2 and signal is input to InPuT 2 sound of InPuT 3 6 exT In is reduced 10 SPEAKER...

Page 11: ...output terminal to connect when recording the sound printed from this device or using other amps in parallel It is a balanced type and pin arrangements are g 13 PRIORIty COntROl VOlUME PRIORIty MUtE I...

Page 12: ...the connection of xlr jack euro Terminal and rcA jack Turn PHAnTOM switch Off if using the unbalanced cable 14 PRIORIty COntROl VOlUME PRIORIty MUtE This is a volume that adjust the volume of InPuT 3...

Page 13: ...PublIc Address MIxIng AMPlIfIer 11 PM 236 248 260 Applications Applications AMP SPK MIXER...

Page 14: ...VEL METER LED DRIVER 50 10 AMP MIC LINE Vph PHANTOM POWER AMP PHANTOM POWER Vph AMP Vph PHANTOM POWER TEMP SENS PROTECTION CIRCUIT 0dBV MIX OUT CHIME SIREN AC IN PWR SMPS 20 0 dBV TEL IN INPUT 1 60 20...

Page 15: ...50 10 AMP MIC LINE Vph PHANTOM POWER AMP PHANTOM POWER Vph AMP Vph PHANTOM POWER TEMP SENS PROTECTION CIRCUIT 0dBV MIX OUT CHIME SIREN PWR SMPS 20 0 dBV TEL IN INPUT 1 60 20dBV INPUT 2 60 20dBV INPUT...

Page 16: ...sensitivity Impedance MIc bAlAnce 60dbV 2k lIne bAlAnce 20dbV 2k rcA unbAlAnce 20dbV 20k 3 5 PHOne JAcK unbAlAnce 20dbV 2k Tel In bAlAnce 20 0dbV 40k exT In bAlAnce 0dbV 40k MIx OuT bAlAnce 0dbV THd...

Page 17: ...PublIc Address MIxIng AMPlIfIer 15 PM 236 248 260 DIMEnSIOnS 88 420 318 7 419...

Page 18: ...is available by contacting your warranty provider Variations and Options Variations and Options Variations Products supplied through legitimate sources are compatible with local Ac power requirements...

Page 19: ......

Page 20: ...ean company but rather a global company that is truly international in scope with factories and offices in Korea and china and sales and marketing operations located in Japan europe and the u s A With...

Reviews: