I N S T A L L A T I O N M A N U A L
D U R O - S P R I N G ™
6
DS-IM Rev. 12/09 (BK-DS INSTALL)
FIG. A – DURO-SPRING PLACEMENT SPECIFICATIONS:
TABLE 3 – PLACEMENT CHART
ADDITIONALLY REFER TO:
ANSI/NSPI-5 2003 American National Standard for Residential Inground Swimming
Pools and to page 5 for Inter-Fab Residential Inground Pool Minimum Specifications.
INTER-FAB CANNOT GUARANTEE CUSTOMER’S CONCRETE OR THICKNESS
NOTE: WHEN COPING IS USED, DO NOT SET FRONT JIG BOLTS CLOSER THAN 3” FROM THE
BACK EDGE OF THE COPING.
NOTE: READ THESE INSTRUCTIONS IN THEIR ENTIRETY BEFORE
ATTEMPTING THE INSTALLATION.
IMPORTANT:
THESE DIMENSIONS
ARE ACCURATE ONLY
FOR VERTICAL POOL
WALLS,
TYPICALLY
GUNITE CONSTRUC-
TION
, WITH LESS
THAN A 3’ RADIUS TO
THE POOL FLOOR.
DUE TO THE VARYING
SIZES OF OTHER
POOLS,
TYPICALLY
VINYL LINER CON-
STRUCTION
, PLEASE
CONTACT CUSTOMER
SERVICE FOR PROPER
JIG PLACEMENT.
1-800-737-5386
DURO-SPRING
PART #
NOMINAL
BOARD
LENGTH
ANSI/
NSPI-5
POOL
TYPE
DISTANCE FROM
WATER’S EDGE TO
FORWARD JIG BOLT
(S)
DISTANCE FROM
END OF BOARD TO
FORWARD JIG BOLT
MAX HEIGHT
OF BOARD
ABOVE
WATER
(HOW)
DSS6
6’
I 27”
45”
18”
20”
DSS6
6’
II
27”
45”
18”
20”
DSS6
6’
III
21”
45”
24”
26”
DSS6
6’
IV
15”
45”
30”
30”
DSS6
6’
V
9”
45”
36”
40”
DSS8
8’
I
DSS8
8’
II
DSS8
8’
III
39.75”
63.75”
24”
26”
DSS8
8’
IV
33.75”
63.75”
30”
30”
DSS8
8’
V
27.75”
63.75”
36”
40”
MIN.
OVERHANG
PLUS OR
MINUS 3”
(WA)
Cannot put 8' jump board on type I pool
Cannot put 8' jump board on type II pool