Read the owners manual carefully before installing the BG!

 Description

The Battery Guard BG40/60/100/200 (hereafter BG) is an intelligent, fully waterproof, battery guard with expansion capabilities for an on/off switch, alarm 

buzzer or relay and our Battery Watch (not supplied). To ensure low losses, the BG is provided with two screw terminals, one Input+ and one . The 
rest, like the minus and the accessories are connected via four 6.3 mm faston connectors. The LED indicates the output status (on/off) of the BG and in the 

programming mode the LED indicates the program position. The BG is provided with an 'Automatic board system detection' with which the BG automatically 
detects what the battery voltage (12V or 24V) of the system is, so that it does not need to be set manually. Both under and over voltage thresholds can be 

easily programmed.

 Installation

Mount the BG on a cooling (metal) surface so that it can release the developed heat. Connect the BG as close as possible to the battery (maximum distance: 

50cm). Only in this way can the voltage be monitored exactly. Any programming of the BG must take place before the equipment (users) can be connected. For
the minus connection use a cable of 1.5 mm2 which goes directly from the battery to the BG and do 

not

 use this connection for anything else.

Warnings:

The product should only be connected by skilled fitters / mechanics, who are aware of the regulations for working with high battery voltages.

Live parts must not come into contact with the housing of the BG.

Use of bad material and / or too thin wires can damage the BG.

A short circuit between the positive and negative terminals of the battery may cause severe damage to your system.

Always use fuses (of the correct value).

 Operation

In the standard programming (position 11 in the "Configuration Table") a buzzer may be connected to the alarm output. This will sound an alarm after 15 
seconds when there is undervoltage. If the situation does not change, the BG will turn off attached devices after 60 seconds and the alarm will be switched off. 

Since with overvoltage there is a risk of damage to the connected equipment this will be switched off immediately when there is overvoltage (16/32V) and the 
alarm output will pulsate. This is done to distinguish between an undervoltage alarm and an overvoltage alarm.

A second application is to connect a relay to the alarm output. The BG must then be programmed in position 12 (see “Programming”). The relay will switch on 
during an alarm and only switch off when reaching the reset value of the undervoltage. The relay can thus be used to activate a charger or generator.

Remote ON / OFF

You can connect a switch to the OFF terminal of the BG. If the OFF terminal is connected to the Minus the BG will immediately switch off the attached devices. 

If the switch is opened again, the BG will switch on again after about 5 seconds. Since the current through the switch is zero (<10mA) a small switch can be 
used.

Battery Watch (optional)

As can be seen in the connection diagram, there may be an optional Battery Watch connected. This is a simple battery status monitor which, by means of 3 

LEDs, indicates the status of the battery. Please contact your dealer.

 Programming

   Configuration Table

To start the programming mode a connection must be made 
between the ProgramInput and Input+. The LED will flash. The 

number of flashes indicates the program position (see table) that 
the BG is in. As soon as the desired program position is reached 

the connection (between the ProgramInput and the Input+) must 
be broken. As confirmation the BG will repeat the number of 

flashes. If it does not match your selection, you can repeat the 
steps.

There are two types of settings that can be applied. Positions 1 to 
10 adjust the threshold and reset values for ??an under voltage 

alarm and the operation of the alarm can be set with positions 11 
and 12. These settings must be made separately (one after 

another). 
When removing the battery voltage the programmed positions 

remain retained. Once the programming is complete, the 
equipment can be connected. First disconnect the battery 

connection, connect the equipment to the  and then 
reconnect the battery.

Note:

Before programming first disconnect the equipment from

the BG.

12 Volt mode

24 Volt mode

undervoltage

reset

undervoltage

reset

Position 1*

10,5

0

V

12

,00

V

Position 1*

21

,00

V

24

,00

V

Position 2

10

,00

V

11,5

0

V

Position 2

20

,00

V

23

,00

V

Position 3

0

9,5

0

V

11,5

0

V

Position 3

19

,00

V

23

,00

V

Position 4

11,25V

13,25V

Position 4

22,5

0

V

26,5

0

V

Position 5

11,5

0

V

13,8

0

V

Position 5

23

,00

V

27,6

0

V

Position 6

10,5

0

V

12,8

0

V

Position 6

21

,00

V

25,6

0

V

Position 7

11,5

0

V

12,8

0

V

Position 7

23

,00

V

25,6

0

V

Position 8

11,8

0

V

12,8

0

V

Position 8

23,6

0

V

25,6

0

V

Position 9

12

,00

V

13

,00

V

Position 9

24

,00

V

26

,00

V

Position 10

10

,00

V

13,2

0

V

Position 10

20

,00

V

26,4

0

V

alarm function

alarm function

Position 11*

Normal alarm

Position 11*

Normal alarm

Position 12

Relais function

Position 12

Relais function

*

Default settings.

Normal alarm

Alarm output is activated in case of emergency: deactivation after 1 minute.

Relaisfunction

Alarm is activated in case of emergency: Deactivation upon reaching the reset voltage.

Battery Guard

Owners Manual BG40_60_100_200 EN_DU_FR_NL 151016

Summary of Contents for BG40

Page 1: ...Battery Guard 40 60 100 200 Owners Manual Gebrauchsanweisung Mode d Emploi Gebruiksaanwijzing Battery Guard Owners Manual BG40_60_100_200 EN_DU_FR_NL 151016 Ref PM AR BP ...

Page 2: ...n reaching the reset value of the undervoltage The relay can thus be used to activate a charger or generator Remote ON OFF You can connect a switch to the OFF terminal of the BG If the OFF terminal is connected to the Minus the BG will immediately switch off the attached devices If the switch is opened again the BG will switch on again after about 5 seconds Since the current through the switch is ...

Page 3: ... Kabel bitte für keinen anderen Zweck verwenden Warnhinweise Das Produkt darf ausschließlich von fachlich versierten Installateuren Monteuren angeschlossen werden die über die Vorschriften zur Arbeit mit Batterien unter Hochspannung vertraut sind Spannung führende Teile dürfen niemals in Kontakt mit dem Gehäuse des BG kommen Bei der Verwendung von schlechtem Anschlussmaterial bzw zu dünnen Drähten...

Page 4: ...arm Positie 12 Relais funktion Positie 12 Relais funktion Standardeinstellungen Normaler alarm Bei einem Alarm wird der Alarmausgang deaktiviert Deaktivierung nach 1 Minute Relaisfunktion Bei einer Alarmmeldung wird der Alarm ausgelöst Deaktivierung beim Erreichen der Rücksetzspannung Technische Daten BG40 BG60 BG100 BG200 Schnittfläche 10mm2 15mm2 30mm2 50mm2 Automatische Erfassung von 12V oder 2...

Page 5: ... le commutateur est nulle 10 mA il est possible d utiliser un petit commutateur Contrôleur de batterie optionnel Comme le montre le schéma de raccordement un contrôleur de batterie Battery Watch peut être raccordé Il s agit d un simple dispositif de surveillance de la batterie qui indique l état de celle ci au moyen de trois indicateurs DEL Veuillez pour cela prendre contact avec votre fournisseur...

Page 6: ...elke direct van de accu naar de BG gaat en gebruik deze aansluiting nergens anders voor Waarschuwingen Het product mag alleen door vakbekwame installateurs monteurs die op de hoogte zijn van de voorschriften voor het werken met hoge accu spanningen worden aangesloten Spanningvoerende delen mogen nooit in aanraking komen met de behuizing van de BG Bij gebruik van slecht aansluitmateriaal en of te d...

Page 7: ...0 00V 23 00V Positie 3 09 50V 11 50V Positie 3 19 00V 23 00V Positie 4 11 25V 13 25V Positie 4 22 50V 26 50V Positie 5 11 50V 13 80V Positie 5 23 00V 27 60V Positie 6 10 50V 12 80V Positie 6 21 00V 25 60V Positie 7 11 50V 12 80V Positie 7 23 00V 25 60V Positie 8 11 80V 12 80V Positie 8 23 60V 25 60V Positie 9 12 00V 13 00V Positie 9 24 00V 26 00V Positie 10 10 00V 13 20V Positie 10 20 00V 26 40V a...

Page 8: ...ansluitschema Battery Guard Owners Manual BG40_60_100_200 EN_DU_FR_NL 151016 Battery Watch optional BATTERY Consumers Input Output Output Fuse _ _ Prog Input Alarm Output Minus Off Input On Off Closed Off Fuse 1A Alarm Buzzer 100 200 40 60 G Ref PM AR BP ...