![Intellijel MIDI1U Manual Download Page 28](http://html1.mh-extra.com/html/intellijel/midi1u/midi1u_manual_2074220028.webp)
Clock Division
Selects a clock division to apply to the incoming MIDI clock.
The divided clock is sent out the
CLK
output.
/1
clock out = 24 ppq
/3
clock out = 1/32 notes
/6
clock out = 1/16 notes
/12
clock out = 1/8 notes
/24
clock out = 1/4 notes
/48
clock out = 1/2 notes
/96
clock out = whole notes
Clock Mode
Always
The
CLK
output
always
transmits a clock, even if the
incoming MIDI clock is stopped. In this case, it continues to
transmit clock using the most recently received clock rate.
Running
The
CLK
output transmits a clock signal only when a MIDI
clock is being received (i.e., is
‘running’
).
RST Output
Reset
The
RST
jack transmits a trigger signal whenever a MIDI
RESET message is received. This is the factory default.
Run
The
RST j
ack transmits a run gate that stays high (5V) for as
long as the external MIDI clock is running. Stopping the
external MIDI clock sets the gate low (0V). This is useful for
starting/stopping any eurorack sequences in sync with an
external MIDI sequencer.
Single Mono MOD Output Settings
Use these settings to configure the source and type of signal sent from the
MOD
jack when
MIDI 1U is set to Single Mode.
IMPORTANT: These setting apply only when MIDI 1U is set to
, since the MOD jack is
used for synth 2’s Pitch output in
).
Output Type
Selects the type of voltage sent out the
MOD
jack. By default,
this is a CC Number (the value of which is selected from the
CC Number
menu), however other assignments are possible.
Specifically:
Clock (Always) The jack outputs a clock signal (timed at the rate set by the
Clock Division
parameter, which appears when
“Clock (Always)” is selected). The clock is output whether or
not the incoming MIDI clock is running (using the most
recently received clock value, if it’s not).
Clock (Running) As with “Clock (Always),” the jack outputs a divided clock
signal, but only when a MIDI clock is being received.
Reset
The jack outputs a trigger signal whenever a MIDI RESET
message is received.
MIDI 1U System Manual