Installing Engage® Zone Control System
Engage® Zone Control Installation Manual
600840-000043, rev 1.4
Page 20 of 31
Installing the whisker switch
Figure 16: Installing the whisker switch
1. Mount the whisker switch (356070-000041) to an existing magnet or to an existing work
switch bracket, if one exists.
NOTE:
You can unscrew the work switch magnet from the bracket and re-attach it to the
other end of the bracket to allow for other mounting orientations.
2. Plug S2 of the work switch extension harness (353050-000011) into the work switch
harness.
Determining work switch method
The work switch uses one of two methods to determine when the implement is in the ground:
•
Default method
o
The work switch is
engaged
(the work switch is triggered by the height sensor) when
the
implement is in the ground
.
o
The work switch is
disengaged
(the work switch is not triggered) when the
implement is out of the ground
.
•
Inverted method
o
The work switch is
disengaged
(the work switch is not triggered) when the
implement is in the ground
.
o
The work switch is
engaged
(the work switch is triggered by the height sensor) when
the implement is
out of the ground
.