background image

11

will be displayed.

Summary of Contents for intell-lab ph series

Page 1: ...June 2009 Intell Lab Precision Toploading Balances PH Series User Operation Manual A Higher Level of Precision A Higher Level of Performance...

Page 2: ...bration 10 16 Tare function 17 Alphanumeric keyboard 18 Manual tare function 19 Weight units 20 PC Interface selection 21 Printer Interface selection 22 Baud rate selection 23 Filters settings 24 Auto...

Page 3: ...which shall be easily accessible after few seconds the balance will automatically switch on Wait 30 minutes from switch on and calibrate the balance using the mass enclosed in the package following th...

Page 4: ...WEIGHING PAN ASSEMBLY June 2009...

Page 5: ...WEIGHING PAN ASSEMBLY 5...

Page 6: ...AND DISPLAY Fig 1 ELECTRONIC BALANCE ON OFF key It confirms selection from MENU key or it controls printing It selects setup MENU CALIBRATION key TARE key Indicator of selected weight UNITS Intell Lab...

Page 7: ...7 9 Pin RS232 Interface Output for PC keyboard and printer Hook for weighing under balance plan P S remove hook cap B1 B2 and B3 are screws for balance closing Fig 2a Bottom view...

Page 8: ...8 ELECTRONIC BALANCE PH Series Weighing pan CONNECTOR 1 9 Pin RS232 Interface Output for PC keyboard and printer Hook for weighing under balance plan P S remove hook cap...

Page 9: ...STAND BY mode To bring the balance to working conditions press ON OFF key To bring it in STAND BY mode press ON OFF key again NORMAL WEIGHING Load the good to weight on the pan and read weight value o...

Page 10: ...key Dashes are displayed c a lib we ight BEL ENGINEERING 200 00 lb oz ct g The display will stop flashing indicating calibration weight value Wait for buzzer BEEP to confirm calibration Unload calibra...

Page 11: ...11 will be displayed...

Page 12: ...r than calibration weight set the balance will recognise as valid a weight equal or higher than calibration weight as long as it is a whole number in comparison with the most meaningful digit of calib...

Page 13: ...13 The balance is ready for weighing operations NOTE if there is an interference during calibration process the message ERROR will be displayed not for Analytical balances...

Page 14: ...weight on the pan Wait for the flashing message 0 to be displayed Unload weight from the pan If calibration operation has been effected correctly the balance will return to normal weighing conditions...

Page 15: ...15 starting from point 2...

Page 16: ...ns are not being effected In this mode in addition to a calibration every 30 minutes it is possible to effect calibration with internal calibration weight by pressing CAL key at any time being sure th...

Page 17: ...bration mode AUT CAL autocalibration I CAL internal calibration E CAL external calibration TEC CAL technical calibration by pressing MENU key in sequence TEC CAL lb oz ct g After selection the balance...

Page 18: ...sure no weight is loaded on the pan Press CAL key at empty pan CAL lb oz ct g The message CAL will be displayed Internal calibration weight is then loaded 0 00 lb oz ct g When the message 0 00 will b...

Page 19: ...19 ons or draughts...

Page 20: ...rmal weighing conditions Intell Lab TARE FUNCTION Press CAL key at empty pan Dashes are displayed lb ct oz g CAL As soon as calibration weight value starts to flash load calibration weight on the pan...

Page 21: ...e stability cannot be reached because of draughts vibrations or other problems dashes will keep on being displayed Load the goods to weight in the container Read net weight value on display Load the c...

Page 22: ...G H I J K L M N O P Q R S T U V 7 8 9 W X 4 5 6 Y Z 1 2 3 0 SP If you have an alphanumeric keyboard it is possible to perform tare pressing TARE DELETE key too in the same way previously described NO...

Page 23: ...value using numerical key located at the bottom part of the alphanumeric keyboard Press INSER to confirm Press ESCAPE key to go out from this condition To set at zero the value of manual tare inserte...

Page 24: ...ROY OUNCES 0 0321 50747 GRANO GRAINS 15 43235835 TAEL HON HONG KONG TAEL 0 02671 725 TAEL SGP SYNGAPORE TAEL 0 02646063 TAEL ROC R O C TAEL 0 02666666 MOMME MOMME 0 2667 x 10 x 10 10 x 100 x 100 100 N...

Page 25: ...il the message PC PRTR is displayed Press key to confirm Press MENU key until the message PC is displayed Press key to confirm NOTE select baud rate page 22 BEL ENGINEERING PC lb ct oz g CAL BEL ENGIN...

Page 26: ...l be display PRINTER for printing of weight only PRT TIM for printing of date hour and weight PRT GLP for printing of GLP data Printing modes PRT TIM and PRT GLP are available only using printer mod C...

Page 27: ...NEERING lb oz 1200 ct g CAL BEL ENGINEERING lb oz 9600 ct g CAL PRINT Select serial data baud rate 1200 2400 4800 9600 baud by pressing MENU key in sequence Confirm baud rate with key BEL ENGINEERING...

Page 28: ...28 Instructions 6K UK Rev 08 doc Page 23 of 46...

Page 29: ...ILTRO 3 stable conditions FILTRO 4 unstable conditions FILTRO 5 very unstable conditions Press MENU key until the message FILTER is displayed BEL ENGINEERING BEL ENGINEERING FILTER 5 oz ct g MENU CAL...

Page 30: ...played Press Select by MENU key Au0 OFF autozero disabled Au0 1 level Au0 2 level Au0 3 level Au0 4 level Press BEL ENGINEERING AUTO 0 lb ct oz g CAL BEL ENGINEERING Au0 OFF lb ct oz g CAL BEL ENGINEE...

Page 31: ...of the single piece Press key to confirm Load on the pan the number of pieces indicated on the display Press key once again Wait for stabilization of the weight If the number of samples is enough for...

Page 32: ...pprox doubled then press key If the quantity of pieces is still not enough the message Add will be displayed again Double again the quantity read on the display On reaching the sufficient number of pi...

Page 33: ...be displayed followed by a short acoustic message Now it is possible to repeat this procedure up to a maximum of 255 pieces or proceed to the normal counting of the pieces This mechanism grants a mor...

Page 34: ...To display weight value during the counting of pieces press MENU key This condition is indicated by lighting of all display arrows To return to piececounting condition and proceed with counting press...

Page 35: ...error press CLEAR key and start again Press INSER key to confirm If the inserted weight is 100 times smaller than balance readability the message ERROR will be displayed To escape without inserting th...

Page 36: ...n the digit placed on the extreme left side of the display The scale at highest sensitivity remains until net weight exceedes in positive max value foreseen for lower range or in negative a fixed limi...

Page 37: ...ssage starts flashing until stability is reached then an acoustic alarm is given out Tare value in water is stored until balance is switched off and it can be changed repeating the same sequence of op...

Page 38: ...ue will be printed once this will be stable pressing PRINT key If weight does not become stable in 10 seconds the message ERROR will be displayed and an acoustic alarm will be emitted The connector to...

Page 39: ...39 Possible non meaningful zeroes are spaces...

Page 40: ...n in the following figure 6 Connecting balance to serial printer To print weight connect connector 1 of the balance to serial printer as shown below Balance 2 Input data Busy signal Side 4 Printer Con...

Page 41: ...41 alphanumeric keyboard...

Page 42: ...42 Connectors located on the rear panel of the balance Fig 2 Rear view panel of balance Mod K Connector 1 Keyboard PC Printer Connector 2 Supply connector...

Page 43: ...LY June 2009 Fig 3 9 8 7 6 5 4 3 2 1 CONNECTOR 1 FOR KEYBOARD OR PC OR PRINTER pin 1 pin 2 pin 3 pin 4 pin 5 5v for keyboard Tx signal PC Rx signal PC busy signal Gnd pin 4 6 connected one with other...

Page 44: ...ivery note 2 Warranty covers all parts resulting defective at the origin It does not cover mechanical or electronic parts damaged by wrong installation tampering or incorrect use 3 Warranty does not c...

Page 45: ...measurement industry both in the USA and worldwide With contacts in over 50 countries we provide you with the weighing and measurement equipment you need QUALITY Products solidly built from the ground...

Page 46: ......

Reviews: