Refuelling Port
Hydrogen Output Port
Pressure Relief Valve
Pressure Transducer
Burst Disc
Cylinder Thread
15
4 Hydrogen connection
4.3 Hydrogen High Flow Light Weight (HFLW) Regulator
The 2.4kW FCPM is designed to be operated with an Intelligent Energy HFLW Regulator.
Note The FCPM could be permanently damaged if operated with incorrect hydrogen
inlet pressure or insufficient hydrogen flow.
4.4 Connecting the FCPM and HFLW Regulator
The HFLW Regulator is designed to be connected to an Intelligent Energy FCPM.
Please refer to the Light Weight (LW) Regulator user manual for details of how to
mount the Regulator to the cylinder. The HFLW regulator gas connections are
identical to the LW Regulator so may be used for reference.
https://www.intelligent-energy.com/uploads/product_guides/53527_IE_-_
Lightweight_Hydrogen_Regulator_User_Manual_August_2019.pdf
Note Ensure the hydrogen cylinder and FCPM are securely mounted
before proceeding.
1. Verify the connector O-rings are in place
and free from damage or debris.
2. Align the hose connector path with
the regulator pins.
3. Push the hose connector and twist anti-clockwise.
It will click when located.