6 SPECIFICATIONS
INPUTS:
Mains Supply
110-240VAC 50-60Hz 2.5KW Max.
OUTPUTS:
Voltage
10.0V Minimum
27.0V Maximum
Current
80A Maximum
OVERLOAD PROTECTION:
105-125% of output power.
Constant power to 75% of set output voltage
then output shuts down, recycle AC to reset
SHORT CIRCUIT PROTECTION:
Output latches off, recycle AC to reset.
METER ACCURACY:
Voltage accuracy
±0.2V
Current Accuracy
±1.0A
ENVIRONMENTAL:
Temp Operating
0°C ~ 40°C
Temp Storage
-10°C ~ 60°C
Humidity
20% - 90% Non condensing
Altitude
0 to 3000 Metres.
IP Rating:
Operating
IP33
Doc: DWG1061-11-R2 LSU80A Operators manual.odt