32-ch Relay
USB or RS-232 Controlled
!aa7dd – Set module’s address
Description
Each device must have a unique network address. This command defines a
module’s address.
One must set the device
value to ‘82’ to enable setting of
device mode register #51 value.
Make sure setting mode register #50 value to its normal setting when done.
Syntax
!aa7dd <CR>
!
Delimiter character
aa
Hexadecimal address of the device
7
Change device baud rate command
dd
New Hexadecimal address
<CR> Carriage Return - End of command
Response
|dd<CR> if the command was valid
Example
Command: !00701<CR>
Response: |01 EE OK<CR>
Change the address of the device at address 0(Hex) to 1(Hex)
1.
Factory default is 00Hex
2.
In products chained system, each product must be set to a unique
address.
3.
The updated address is displayed on the boards 7 segment led display.
Note
!