background image

 Installation instructions/User instructions

SAVE THESE INSTRUCTIONS

Fulfils the requirements 
of NEK 400:2014

Mkomfy 2G R-T 25A

 Panel-installed cooker guard relay

Mkomfy set with sensor and relay 

is supplied ready paired and ready for use 

Summary of Contents for Mkomfy 2G R-T 25A

Page 1: ...ructions User instructions SAVE THESE INSTRUCTIONS Fulfilstherequirements ofNEK400 2014 Mkomfy 2G R T 25A Panel installed cooker guard relay Mkomfy set with sensor and relay is supplied ready paired a...

Page 2: ...her sound signal is heard Anti tamper function If the sensor is removed from its bracket a safety function is activated and cuts off the power to the cooker On activation the sensor will beep once a s...

Page 3: ...cold cooker elements Battery change Battery change is normally only necessary after approx 6 years use The sensorwillwarn about battery change when necessary This will be done by 2 short sound signals...

Page 4: ...e it is very important that the wall is carefully cleaned prior to mounting and that the wall is completely free from moisture after cleaning NB The sensor must be positioned horizontally and in the c...

Page 5: ...ng Mounting height Height 1 Standard 50 70 cm Height 2 71 90 cm Height 3 91 105 cm Height 4 106 120 cm Mounting distances The straight line distance from the sensor eye to the centre of the hob must n...

Page 6: ...centre of the cooker s width dimension and mark off where the bracket is to go 2 Pull the sensor off the bracket NB Do not release the set screw 3 Screw the bracket using the screws supplied to the l...

Page 7: ...1 Remove the set screw 2 Hold the function button in for 20 seconds The light beam will flash for 60 seconds 3 Rotate the sensor so the light beam hits the centre of the hob 4 Tighten the set screw at...

Page 8: ...sh All connected units are now deleted Installation information Blue Yellow Red Green Programming button Green Lights up continuously while the relay is connected Flashes if there is no communication...

Page 9: ...dio contact it will start to beep and the function test will run If the sensor does not have radio contact see Pairing page 11 NB After 2 minutes the function test will deactivate Remember to deactiva...

Page 10: ...to Relay again for 5 seconds by turning the relevant protection circuit off and on NB This must be done within one minute of powering the relay under Point 2 or the pairing will not be saved 4 Set DI...

Page 11: ...i 10 sek en gang til for g tilbake til 2 timer drift ett lydsignal OBS P se at du har nye batterier tilgjengelig Alarms signals with use of Mkomfy Alarm signal One 1 sound signal every 15 seconds Cau...

Page 12: ...Mkomfy 2G R T 25A Chrome 6251662 Mkomfy 2G R T 25A Black 6251663 Mkomfy 2G R T 25A White Technical data Mkomfy Komfyrvakt R T 25A Voltage 230 VAC 10 Max load 25 A Physical dimensions sensor 83x32 mm T...

Reviews: