background image

10

Pairing of Sensor and Relay 

The Mkomfy set with sensor and relay in the same pack are already 
paired. If you have bought a separate sensor, this must be paired with 
the relay. 
This can be done in two different ways. 

Read through the whole instruction for both alternatives before performing pairing!

Alternative 1: 

Pairing of Sensor without physical intervention on relay.

1. 

Activate Sensor in pairing mode by setting DIPSW6 to active [ON]. 

2. 

Disconnect the power to Relay for 5 seconds by turning the 
relevant protection circuit off and on.  
- Within 20 seconds of turning the protection circuit on:  
 

Hold in the function button on the sensor for 6 seconds.  

The sensor will emit a sound signal every 2 seconds, if pairing 
has succeeded.

3. 

Disconnect the power to Relay again for 5 seconds by turning 
the relevant protection circuit off and on. 

 

NB! This must be done within one minute of powering the relay 

under Point 2, or the pairing will not be saved

4. 

Set DIPSW 6 back to inactive [OFF].

  

Pairing is now complete.

Alternative 2: 

Pairing of Sensor by activation of programming button on relay.

1. 

Activate Sensor in pairing mode by setting DIPSW6 to active [ON].

2. 

Briefly press the programming button on Relay. Yellow diode 
will now begin to flash. The relay will now be in pairing mode 
for 30 seconds. 

3. 

Hold in the function button on the sensor for 6 seconds while 
the yellow LED flashes. The sensor will emit a sound signal every 
2 seconds, if pairing has succeeded. 

4. 

Set DIPSW 6 back to inactive [OFF].

NB: It is not possible to have more than 1 Mkomfy Sensor connected to the Relay 
at the same time. Pairing a new sensor will automatically delete the sensor 
already paired with the Relay. 

Installation information

Summary of Contents for Mkomfy 2G R-T 25A

Page 1: ...ructions User instructions SAVE THESE INSTRUCTIONS Fulfilstherequirements ofNEK400 2014 Mkomfy 2G R T 25A Panel installed cooker guard relay Mkomfy set with sensor and relay is supplied ready paired a...

Page 2: ...her sound signal is heard Anti tamper function If the sensor is removed from its bracket a safety function is activated and cuts off the power to the cooker On activation the sensor will beep once a s...

Page 3: ...cold cooker elements Battery change Battery change is normally only necessary after approx 6 years use The sensorwillwarn about battery change when necessary This will be done by 2 short sound signals...

Page 4: ...e it is very important that the wall is carefully cleaned prior to mounting and that the wall is completely free from moisture after cleaning NB The sensor must be positioned horizontally and in the c...

Page 5: ...ng Mounting height Height 1 Standard 50 70 cm Height 2 71 90 cm Height 3 91 105 cm Height 4 106 120 cm Mounting distances The straight line distance from the sensor eye to the centre of the hob must n...

Page 6: ...centre of the cooker s width dimension and mark off where the bracket is to go 2 Pull the sensor off the bracket NB Do not release the set screw 3 Screw the bracket using the screws supplied to the l...

Page 7: ...1 Remove the set screw 2 Hold the function button in for 20 seconds The light beam will flash for 60 seconds 3 Rotate the sensor so the light beam hits the centre of the hob 4 Tighten the set screw at...

Page 8: ...sh All connected units are now deleted Installation information Blue Yellow Red Green Programming button Green Lights up continuously while the relay is connected Flashes if there is no communication...

Page 9: ...dio contact it will start to beep and the function test will run If the sensor does not have radio contact see Pairing page 11 NB After 2 minutes the function test will deactivate Remember to deactiva...

Page 10: ...to Relay again for 5 seconds by turning the relevant protection circuit off and on NB This must be done within one minute of powering the relay under Point 2 or the pairing will not be saved 4 Set DI...

Page 11: ...i 10 sek en gang til for g tilbake til 2 timer drift ett lydsignal OBS P se at du har nye batterier tilgjengelig Alarms signals with use of Mkomfy Alarm signal One 1 sound signal every 15 seconds Cau...

Page 12: ...Mkomfy 2G R T 25A Chrome 6251662 Mkomfy 2G R T 25A Black 6251663 Mkomfy 2G R T 25A White Technical data Mkomfy Komfyrvakt R T 25A Voltage 230 VAC 10 Max load 25 A Physical dimensions sensor 83x32 mm T...