Alarm Signal: 

One (1) alarm

 every 30 seconds.

Indicates:    

5 minutes left of the 2 hours timer function 

 

 

before switching off the kitchen stove.

Action:  

Push button for another 30 minutes in operation.

Alarm Signal: 

Two (2) alarms 

every five minutes.

Indicates:  

Battery change is needed.

Action:  

Remove the Sensor from the bracket without twisting it.

  

Note!

 Do not loosen the screw!

 

 

Remove the lid, and replace the batteries (2xAAA).

 

 

Mount the sensor back into the mounting bracket in

 

 

correct lock position.

DIFFERENT ALARM SITUATIONS WHEN USING MKOMFY

Alarm Signal: 

Three (3) alarms 

every 5 second lasting for 40 seconds, 

 

 

and LED flashing.

Indicates:    

Over heating.

Action:  

Push button and perform an action to lower the 

 

 

temperature within 5 minutes.

NO RESPONSE

Indicates:    

No Power.

Action:  

Push button.  

  

Note!

 If it doesn’t work, replace the batteries as described 

above.

Note! If none of these steps are helping, try to turn off the main fuse for the stove in the 

fuse box, and then turn the fuse on again.

You will then get power supplied to the stove for the next 24 hours. Then call your electrician for 

further troubleshooting.

NOTE that the security functions are not activated in this period.

Phone: +47 464 88 100 (Mon. – Fri.: 08:00 – 15:00)

Alarmsignal: 

Ett (1) lydsignal 

hvert 30. sekund.

Årsak: 

 

5 minutter funksjonstid gjenstår

 

 

av 2-timers ”Timer-funksjon”.

Tiltak: 

 

Trykk på funksjonsknappen for nye 30 minutter              

                                     funksjonstid.

Alarmsignal: 

To (2) lydsignal 

hvert femte minutt.

Årsak: 

 

Batteribytte er nødvendig.

Tiltak: 

 

Trekk sensoren ut av festet uten å vri rundt på den.

 

 

NB: Settskrue skal ikke løsnes!

 

 

Ta av lokket, og sett i 2 nye batterier (2xAAA).

 

 

Sett sensoren tilbake i festet i riktig låseposisjon. 

FORSKJELLIGE ALARMSIGNAL VED BRUK AV MKOMFY

Alarmsignal: 

Tre (3) lydsignal 

hvert 5. sekund som vil vedvare i 

 

 

40 sekunder og LED blinker.

Årsak:  

Overoppheting.

Tiltak: 

 

Trykk på funksjonsknappen og gjør tiltak ved for eks. å 

 

 

skru ned varmen innen 5 minutter.

INGEN RESPONS 

Årsak: 

 

Ikke strøm på komfyren.

Tiltak: 

 

Trykk på funksjonsknappen.

  

OBS! 

Dersom dette ikke virker, sett inn nye batterier 

 

 

i sensoren som beskrevet ovenfor.

OBS! Hvis ingen av tiltakene ovenfor hjelper, slå ut og inn sikringene 

for komfyrkursen. Du vil nå ha strøm for 24 timer. 

Bruk denne tiden til å tilkalle elektriker for å finne årsaken til problemet. 

OBS! I denne 24-timersperioden er IKKE sikkerhetsfunksjonene aktive.

LED

Function button

LED

Button

Tlf: 464 88 100 (Man. – Fre.: 08:00 – 15:00)

47.13

47.13

Endring av Timer

Hold funksjonsknapp i 10 sek for å få 

12 timer drift

 på platetopp (to lydsignal).

Hold i 10 sek en gang til for å gå tilbake til 

2 timer drift

 (ett lydsignal).

Change timer function

Push button for 10 seconds to get 

12 hour operating time

 (two beeps).

Push button for 10 seconds again to get 

2 hour operating time

 (one beep).

OBS! 

Påse at du har 

nye batterier 

tilgjengelig

Note!

 Ensure that new 

batteries are available.

Alarms signals with use of Mkomfy

Alarm signal:

One (1) sound signal 

every 15 seconds.

Cause:

In the last 5 minutes of the timer function.

Action:

Press the button for an extra 30 minutes of function time.

Alarm signal:

One (1) sound signal 

every second for 5 seconds.

Cause:

Anti-tamper function detects that the sensor has been 
removed from the bracket.

Action:

Replace the sensor in the bracket and press the button.

Alarm signal:

Two (2) sound signals 

every five minutes.

Cause:

Battery change necessary.

Action:

Pull the sensor from the bracket. Flip off the cover and insert 
new AAA batteries. See more in User instructions page 3.

Alarm signal:

Three (3) sound signals

 every 5 seconds, lasting for max. 

40 seconds, and the LED flashes.

Cause:

Overheating.

Action:

Press the button and take action, e.g. by turning down the 
heat, within 5 minutes. 

NO RESPONSE

Cause:

No power to the cooker.

Action:

Press the button. NB If this does not work, insert new 
batteries in the sensor as described above.

NB If none of these actions work, turn the fuses 

on the cooker circuit off and on. You will now 

have power for 12 hours. Use this time to call an 

electrician to find the source of the problem. 

This is an emergency mode. NOTE that the safety 

function is NOT active in this period. 

The relay beeps once every 30 seconds for the first 

5 minutes after activating the emergency mode.

User information

Summary of Contents for Mkomfy 2G R-T 25A

Page 1: ...ructions User instructions SAVE THESE INSTRUCTIONS Fulfilstherequirements ofNEK400 2014 Mkomfy 2G R T 25A Panel installed cooker guard relay Mkomfy set with sensor and relay is supplied ready paired a...

Page 2: ...her sound signal is heard Anti tamper function If the sensor is removed from its bracket a safety function is activated and cuts off the power to the cooker On activation the sensor will beep once a s...

Page 3: ...cold cooker elements Battery change Battery change is normally only necessary after approx 6 years use The sensorwillwarn about battery change when necessary This will be done by 2 short sound signals...

Page 4: ...e it is very important that the wall is carefully cleaned prior to mounting and that the wall is completely free from moisture after cleaning NB The sensor must be positioned horizontally and in the c...

Page 5: ...ng Mounting height Height 1 Standard 50 70 cm Height 2 71 90 cm Height 3 91 105 cm Height 4 106 120 cm Mounting distances The straight line distance from the sensor eye to the centre of the hob must n...

Page 6: ...centre of the cooker s width dimension and mark off where the bracket is to go 2 Pull the sensor off the bracket NB Do not release the set screw 3 Screw the bracket using the screws supplied to the l...

Page 7: ...1 Remove the set screw 2 Hold the function button in for 20 seconds The light beam will flash for 60 seconds 3 Rotate the sensor so the light beam hits the centre of the hob 4 Tighten the set screw at...

Page 8: ...sh All connected units are now deleted Installation information Blue Yellow Red Green Programming button Green Lights up continuously while the relay is connected Flashes if there is no communication...

Page 9: ...dio contact it will start to beep and the function test will run If the sensor does not have radio contact see Pairing page 11 NB After 2 minutes the function test will deactivate Remember to deactiva...

Page 10: ...to Relay again for 5 seconds by turning the relevant protection circuit off and on NB This must be done within one minute of powering the relay under Point 2 or the pairing will not be saved 4 Set DI...

Page 11: ...i 10 sek en gang til for g tilbake til 2 timer drift ett lydsignal OBS P se at du har nye batterier tilgjengelig Alarms signals with use of Mkomfy Alarm signal One 1 sound signal every 15 seconds Cau...

Page 12: ...Mkomfy 2G R T 25A Chrome 6251662 Mkomfy 2G R T 25A Black 6251663 Mkomfy 2G R T 25A White Technical data Mkomfy Komfyrvakt R T 25A Voltage 230 VAC 10 Max load 25 A Physical dimensions sensor 83x32 mm T...

Reviews: