![Intellian v100Ka Installation And Operation Manual Download Page 57](http://html1.mh-extra.com/html/intellian/v100ka/v100ka_installation-and-operation-manual_2073860057.webp)
57
OPERATING THE ACU
Diagnosis Code:
CODE 101: The data communication between the antenna and the ACU is tested.
CODE 102: The azimuth motor is tested.
CODE 103: The elevation motor is tested.
CODE 104: The cross-level motor is tested.
CODE 105: The azimuth encoder is tested.
CODE 106: The cross-level encoder is tested.
CODE 107: The rate sensor is tested.
CODE 108: The tilt sensor is tested.
CODE 109: The sensor box motor is tested.
CODE 110: The LNB/NBD is tested.
CODE 111: The LNB pol motor is tested.
CODE 112: The sub-reflector is tested. (Skip for v-Series communication products)
CODE 113: The antenna power is tested.
CODE 114: The ACU power is tested.
CODE 115: The receiver power is tested.
(Skip for v-Series communication products)
CODE 116: The home sensor is tested.
An example of test result:
•
2
•••••••••
-
••
-
•
•
: test is passed
2: test has failed (CODE102)
–: test has been skipped (TVRO products only)
?: test is in process