62
Intellian Satellite TV Antenna Systems
- Threshold Setting
• Initial Sat Count: Set the threshold count for maintaining tracking.
• Set Verify Time:Set the time of verifying whether the signal detected is
the signal of target satellite.
• Voltage Threshold: Set the voltage threshold. The voltage threshold is
to distinguish the voltage between 13V and 18V.
• DiSEqC Threshold: Set the DiSEqC threshold. The DiSEqC threshold is
to distinguish the 0KHz tone and 22KHz tone.
• WRS Detect Level: Set the WRS detection level.
- Flag Setting
• Use WRS Method: Use WRS method is to determine whether the
system uses “WRS Detect Level” or not. Use WRS method and “WRS
Detect Level” are pair functions.
• Use Offset Difference: Use offset difference is to determine whether
the system uses “Offset Difference” or not. Use Offset Difference and
“Offset Difference” are pair functions.
• Use DiSEqC 1.2: Use DiSEqC 1.2 is to determine whether the system
uses “DiSEqC 1.2” or not.
3. Satellite (Satellite View)
The name, longitude, verification method of the satellite and LNB local
frequency are displayed.
- LNB Local Frequency: Displays or sets LNB local frequency and its
corresponding LNB voltage supplied. You may select pre-programmed
LNB LO settings from the drop down list..