29
3.24. PGM outputs of PGM expanders (as of version 1.3.0)
To program the expanders’ PGMs 4 to 19, type:
Enter + 8 + ? + ? + ? + ? ? + Enter
5 = exp. PGM Nº 1
6 = exp. PGM Nº 2
7 = exp. PGM Nº 3
8 = exp. PGM Nº 4
1 = 1st PGM of each expander
2 = 2nd PGM of each expander
3 = 3rd PGM of each expander
4 = 4th PGM of each expander
Events that trigger the PGMs
00 = activates PGM via password, remote,
Remote AMT, Mobile AMT and SMS
01 to 64 = activates PGM according to the
triggering of zones 01 to 64
65 to 68 = activates PGM according to the
activation of partitions A, B, C and D
69 to 72 = activates PGM according to the
triggering of partitions A, B, C and D
Operation mode
0 = on/off (for events from 00 to 68)
1 to 8 = pulse (for events from 00 to 68)
9 = siren time (for events from 69 to 72)
3.25. Clearing low battery and bus trouble indication
Enter + Enter
3.26. Editing XAT 2000 LCD/XAT 4000 LCD keyboard messages
Note:
From version 3.30 onward of the AMT 4010 SMART and AMT 4010 SMART
NET, it will not be possible to edit the center’s messages. Editing will only be possible
through the Remote AMT or the Remote AMT App.
Enter + ? + Ac ?? + Enter
? = 1 name of the alarm center
? = 2 users
? = 3 zones
? = 4 bus devices
? = 5 wireless panic user
? = 6 wireless fire user
? = 7 editable message
Summary of Contents for AMT 4010 Smart
Page 1: ...Installation Guide AMT 4010 Smart AMT 4010 Smart Net...
Page 43: ......