21
Time interval for date and time synchronization
Three-digit time interval from 000 to 255 hours
000 = disabled
Enter + 4 0 3 + ? ? ? + Enter
Time zone
Enter + 4 0 5 + Time zone + Enter
Time zone goes from 000 (disabled) to 012. 002 is the time zone for Fernando de
Noronha, 003 for Brasília, 004 for Manaus and 005 for Rio Branco.
Enable Smart function (supervision)
Enter + 516 + Enter + select fu Enter
Key
1
Smart Function
Key
2
Siren triggering due to
Smart system failure
Setting the time for the Smart function connectivity test
Enter + 57 + ? + Enter
? = 1 = 36 min
2 = 72 min
3 = 108 min
4 = 144 min
5 = 180 min
Note:
»
The more likely it is that the sensors installed at the site will be triggered at the
same time, the longer the time programmed for this function should be.
»
As of version 5.0 the Smart Supervision Time function has been removed and set
to 180 minutes.
Example:
1. In places with few installed sensors, but with several simultaneous activations, the
programmed time should be longer.
2. In places with many installed sensors, but with little simultaneous activation of the
sensors, the programmed value for this function should be lower.