17
3.10. Manual bus scan (as of version 3.80)
To enable:
Enter + 518 + enter
Key
5
Manual scan mode
To perform manual scan:
Enter + 37 + enter
3.11. Timing
(Programming only by the installer)
Entry Timer Programming
Enter + 42 + ? + ??? + Enter
? = partition
0 = timing of partition A
1 = timing of partition B
2 = timing of partition C
3 = timing of partition D
??? = entry time from 000 to 255 seconds
If ??? = 000, entry timer disabled
Exit Timer Programming
Enter + 44 + ??? + Enter
??? = exit time from 000 to 255 seconds
If ??? = 000 exit timer disabled
Clock programming
Enter + 400 + HH + MM + SS + Enter
HH = two-digit hours in 24h format
MM = two-digit minutes
SS = two-digit seconds
Fine tuning of the center clock’s seconds
Enter + 405 + SSS + Enter