Error Reporting and Handling
Intel® SHG2 DP Server Board Technical Product Specification
Intel Order Number C11343-001
Revision 1.0
46
Code
Error Message
Failure Description
0B51:
Processor #2 with error taken offline
Failed Processor 2 because an error was detected.
0B52
Processor #3 with error taken off line
0B53
Processor #4 with error taken off line
0B5F:
Forced to use CPU with error
Failed Processor 3 because an error was detected.
Failed Processor 4 because an error was detected.
An error detected in the entire CPU.
0B60:
DIMM bank 1 has been disabled
Memory error, memory bank 1 failed
0B61:
DIMM bank 2 has been disabled
0B62:
DIMM bank 3 has been disabled
Memory error, memory bank 2 failed
Memory error, memory bank 3 failed
0B6F:
DIMM bank with error is enabled
An error detected in all the memory
0B70:
The error occurred during temperature sensor
reading
Error while detecting a temperature failure.
0B71:
System temperature out of the range
Temperature error detected.
0B74:
The error occurred during voltage sensor reading
0B75:
System voltage out of the range
Error while detecting voltage
System voltage error
0B7C: The error occurred during redundant power module
confirmation.
The error occurred while retrieving the power
information.
0B80:
BMC Memory Test Failed
BMC device (chip) failed
0B81:
BMC Firmware Code Area CRC check failed
0B82:
BMC core Hardware failure
0B83:
BMC IBF or OBF check failed
Access to BMC address failed
0B90:
BMC Platform Information Area corrupted.
BMC device(chip) failed
0B91:
BMC update firmware corrupted.
0B92:
Internal Use Area of BMC FRU corrupted.
SROM storing chassis information failed
(Available for use except for FRU command and
EMP function)
0B93:
BMC SDR Repository empty.
BMC device (chip) failed
0B94:
IPMB signal lines do not respond.
SMC(Satellite Management Controller) failed
(Available for use except for the access function to
SMC via IPMB)
0B95
BMC FRU device failure.
SROM storing chassis information failed
(Available for use except for FRU command and
EMP function.)
0B96
BMC SDR Repository failure.
BMC device (chip) failed
6.5.4
Liquid Crystal Display (LCD)
There are three users of the LCD: BMC, BIOS, and software. Sometimes they may be using the
LCD simultaneously.
6.5.4.1 BIOS
Usage
The BIOS uses the first line of the LCD. It uses the LCD for messages related to failures and
other conditions. The BIOS generates an LCD message during POST and as a result of errors
handled by the BIOS SMI handler. Unless the LCD has been forcibly reserved by software (via