Intel® Server Compute Blade SBXD62 Installation and User’s Guide
27
Installing an I/O-expansion Card
If I/O-expansion is supported by the Intel® Blade Server Chassis SBCE in which the
blade server is installed, you can add an I/O-expansion card to the blade server. I/O-
expansion cards give the blade server additional connections for communicating on a
network. Your blade server supports the installation of one I/O-expansion card of small-
form-factor or standard-form-factor design.
You can install a small-form-factor expansion card in addition to two SAS hard disk
drives.
The blade server supports a number of daughter cards, such as:
•
Gigabit Ethernet expansion card
•
Fibre Channel expansion card
When you add an I/O-expansion card, you must make sure that the I/O-modules it is
mapped to both support the expansion card network-interface type. These I/O-modules are
typically installed in I/O-module bays 3 and 4 on the Intel® Blade Server Chassis SBCE.
For example, if you add an Ethernet expansion card to a blade server installed in a Intel®
Blade Server Chassis SBCE, the I/O-modules in I/O-module bays 3 and 4 must both be
compatible with the expansion card. All other expansion cards that are installed on other
blade servers in the Intel® Blade Server Chassis SBCE must also be compatible with
these I/O-modules. In this example, you could then install two Ethernet switch modules,
two pass-thru modules, or one Ethernet switch module and one pass-thru module. Because
pass-thru modules are compatible with a variety of I/O-expansion cards, installing two
pass-thru modules would enable the use of several different types of compatible I/O-
expansion cards on blade servers within the same Intel® Blade Server Chassis SBCE.
To install a small-form-factor expansion card, complete the following steps:
1. Read the safety information beginning on
page 65 in Appendix C, “Safety
Information”
and
“Installation Guidelines” on page 15
.
2. Shut down the operating system, turn off the blade server, and remove the blade server
from the Intel® Blade Server Chassis SBCE. See
“Removing the Blade Server from
an Intel® Blade Server Chassis SBCE” on page 17
for instructions.
3. Carefully lay the blade server on a flat, non-conductive surface.
4. Open the cover (see
“Opening the Blade Server Cover” on page 18
for instructions).
Summary of Contents for SBXD62 - Server Compute Blade
Page 8: ...viii Intel Server Compute Blade SBXD62 Installation and User s Guide...
Page 64: ...54 Intel Server Compute Blade SBXD62 Installation and User s Guide...
Page 68: ...58 Intel Server Compute Blade SBXD62 Installation and User s Guide...
Page 98: ...88 Intel Server Compute Blade SBXD62 Installation and User s Guide Intel Intel Intel Web UL...
Page 99: ...Intel Server Compute Blade SBXD62 Installation and User s Guide 89 ITE ITE 5V...
Page 100: ...90 Intel Server Compute Blade SBXD62 Installation and User s Guide...
Page 101: ...Intel Server Compute Blade SBXD62 Installation and User s Guide 91 ESD ESD ESD ESD ESD...
Page 102: ...92 Intel Server Compute Blade SBXD62 Installation and User s Guide...
Page 106: ...96 Intel Server Compute Blade SBXD62 Installation and User s Guide...
Page 118: ...108 Intel Server Compute Blade SBXD62 Installation and User s Guide...