![Intel SBCEFCSW Installation Manual Download Page 33](http://html1.mh-extra.com/html/intel/sbcefcsw/sbcefcsw_installation-manual_2072037033.webp)
19
information, see the diagnostic section of the Intel
®
Blade Server Switch Module SBCEFCSW: Management
and User’s Guide.
Table 2. Switch module LED diagnostic flash patterns
LED
LED activity
OK
•
The LED is off during initialization and POST or when there is a system fault.
•
The LED is lit during LED test and when the switch module is operational.
•
The LED does not flash.
Heartbeat
•
The LED is off when you reset the blade server and when the Fibre Channel
switch module processor is not operational.
•
The LED is lit steady on only during LED test.
•
The LED flashes to indicate the following conditions:
—
Normal operation - The LED flashes at a steady rate of one flash per second.
—
Internal firmware failure - The LED flashes two times, at twice the normal rate,
followed by a 2-second pause.
—
Fatal error - The LED flashes three times, at twice the normal rate, followed by
a 2-second pause.
—
Configuration file system error - The LED flashes four times, at twice the
normal rate, followed by a 2-second pause.
✏
NOTE
See the diagnostic section of the
Intel
®
Blade Server Switch Module
SBCEFCSW: Management and User’s Guide
for more information
about diagnostic flash patterns.
Switch fault
•
The LED is off during initialization or when the switch module is in normal
operation.
•
The LED is lit during LED test or to indicate a system fault during a POST failure or
thermal fault.
•
The LED does not flash.
Port logged-in
•
The LED is off when the port is not logged in.
•
The LED is lit when the port is logged-in or during LED test.
•
The LED pattern indicates the following conditions:
—
Logged in - The LED is lit.
—
Logging in - The LED flashes at 1-second intervals.
—
Beacon location - The LED flashes at 1-second intervals. For more
information, see the
Fibre Channel Switch Management User’s Guide
.
—
Error - The LED flashes two times per second.
Port activity
•
The LED is off when the port is not logged in or when the port is logged in and
there is no port activity.
•
The LED is lit during LED test.
•
The LED flashes when port activity performs a normal send or receive operation.
Port fault
•
The LED is off when port diagnostics starts and is completed without error.
•
The LED is lit when port diagnostics discovers a port error.
•
The LED does not flash.
Summary of Contents for SBCEFCSW
Page 4: ...iv Intel Server Switch Module SBCEFCSW Installation Guide...
Page 14: ...xiv Intel Server Switch Module SBCEFCSW Installation Guide...
Page 22: ...8 Intel Server Switch Module SBCEFCSW Installation Guide...
Page 30: ...16 Intel Server Switch Module SBCEFCSW Installation Guide...
Page 34: ...20 Intel Server Switch Module SBCEFCSW Installation Guide...
Page 56: ...42 Intel Server Switch Module SBCEFCSW Installation Guide...
Page 58: ...44 Intel Server Switch Module SBCEFCSW Installation Guide...