![Intel SBCEFCSW Installation Manual Download Page 29](http://html1.mh-extra.com/html/intel/sbcefcsw/sbcefcsw_installation-manual_2072037029.webp)
15
Figure 5. Fibre Channel switch module release latch
Attention: If you do not replace the switch module, you must insert a filler module into the empty bay
within 1 minute.
6.
Slide the switch module out of the bay and set it aside. Within 1 minute, place either another switch
module or a filler module in the bay.
✏
NOTE
To verify that the switch module is active after you replace it, see Step 10 and Step 11 on page 13.
7.
If you placed another switch module into the bay, if needed, insert any SFP modules that you removed
in
4 into external Fibre Channel port 1 and Fibre Channel port 2. For SFP module installation
instructions, see the documentation that comes with your SFP module.
8.
If needed, use LC-LC fiber-optic cables to connect the switch module external port to external Fibre
Channel devices. For more information, see the documentation that comes with your cable options.
9.
Replace the acoustic attenuation module option, if you removed it in Step 2
.