Power Subsystem
Intel® Server System R2000LH2/T2 Product Family TPS
Revision 1.0
18
3.2
Power Connectors
3.2.1
Power Supply Module Card Edge Connector
Each power supply module has a single 2x25 card edge output connection that plugs directly
into a matching slot connector on the server board. The connector provides both power and
communication signals to the server board. The following table defines the connector pin-out.
The connector pin out in table applies to the 1600W (AC) and 1600W (DC) power supplies.
Note: Mixing of AC and DC power supplies in the same system is unsupported.
Table 5. Power Supply Module Output Power Connector Pin-out
Pin
Name
Pin
Name
A1
GND
B1
GND
A2
GND
B2
GND
A3
GND
B3
GND
A4
GND
B4
GND
A5
GND
B5
GND
A6
GND
B6
GND
A7
GND
B7
GND
A8
GND
B8
GND
A9
GND
B9
GND
A10
+12V
B10
+12V
A11
+12V
B11
+12V
A12
+12V
B12
+12V
A13
+12V
B13
+12V
A14
+12V
B14
+12V
A15
+12V
B15
+12V
A16
+12V
B16
+12V
A17
+12V
B17
+12V
A18
+12V
B18
+12V
A19
PMBus SDA
B19
A0 (SMBus address)
A20
PMBus SCL
B20
A1 (SMBus address)
A21
PSON
B21
12V stby
A22
SMBAlert#
B22
Cold Redundancy Bus
A23
Return Sense
B23
12V load share bus
A24
+12V remote Sense
B24
No Connect
A25
PWOK
B25
Compatibility Check