background image

Intel® Server System R2000WF Product Family Technical Product Specification 

 

 

121 

KVM redirection includes a “soft keyboard” function. The “soft keyboard” is used to simulate an entire 
keyboard that is connected to the remote system. The “soft keyboard” functionality supports the following 
layouts: English, Dutch, French, German, Italian, Russian, and Spanish. 
The KVM-redirection feature automatically senses video resolution for best possible screen capture and 
provides high-performance mouse tracking and synchronization. It allows remote viewing and configuration 
in pre-boot POST and BIOS setup, once BIOS has initialized video.   

Other attributes of this feature include: 

 

Encryption of the redirected screen, keyboard, and mouse 

 

Compression of the redirected screen.   

 

Ability to select a mouse configuration based on the OS type.   

 

Support user definable keyboard macros.   

KVM redirection feature supports the following resolutions and refresh rates: 

 

640x480 at 60Hz, 72Hz, 75Hz, 85Hz, 100Hz 

 

800x600 at 60Hz, 72Hz, 75Hz, 85Hz 

 

1024x768 at 60Hx, 72Hz, 75Hz, 85Hz 

 

1280x960 at 60Hz 

 

1280x1024 at 60Hz 

 

1600x1200 at 60Hz 

 

1920x1080 (1080p) at 60Hz 

 

1920x1200 (WUXGA+) at 60Hz 

 

1650x1080 (WSXGA+) at 60Hz 

11.3.2

 

Remote Console 

The Remote Console is the redirected screen, keyboard and mouse of the remote host system. To use the 
Remote Console window of your managed host system, the browser must include a Java* Runtime 
Environment plug-in. If the browser has no Java support, such as with a small handheld device, the user can 
maintain the remote host system using the administration forms displayed by the browser. 
The Remote Console window is a Java Applet that establishes TCP connections to the BMC. The protocol 
that is run over these connections is a unique KVM protocol and not HTTP or HTTPS. This protocol uses 
ports #7578 for KVM, #5120 for CDROM media redirection, and #5123 for Floppy/USB media redirection. 
When encryption is enabled, the protocol uses ports #7582 for KVM, #5124 for CDROM media redirection, 
and #5127 for Floppy/USB media redirection. The local network environment must permit these 
connections to be made, that is, the firewall and, in case of a private internal network, the NAT (Network 
Address Translation) settings have to be configured accordingly.   
 

11.3.3

 

Performance 

The remote display accurately represents the local display. The feature adapts to changes to the video 
resolution of the local display and continues to work smoothly when the system transitions from graphics to 
text or vice-versa. The responsiveness may be slightly delayed depending on the bandwidth and latency of 
the network.   
Enabling KVM and/or media encryption will degrade performance. Enabling video compression provides the 
fastest response while disabling compression provides better video quality. 
For the best possible KVM performance, a 2Mb/sec link or higher is recommended. 

Summary of Contents for R2000WF series

Page 1: ...er Products and Solutions Intel Server System R2000WF Product Family Technical Product Specification An overview of product features functions architecture and support specifications Revision 1 2 Nove...

Page 2: ...Blank page...

Page 3: ...iagram Added QAT information Server Board Product Family Feature Set S2600WFQ Architecture Block Diagram Edited bullet on the section 4 1 1 Memory Slot Population Requirements Added subsection 3 3 8 D...

Page 4: ...is document The products described may contain design defects or errors known as errata which may cause the product to deviate from published specifications Current characterized errata are available...

Page 5: ...Cable Routing Channels 33 2 10 Available Rack and Cabinet Mounting Kit Options 34 2 11 System Level Environmental Limits 35 2 12 System Packaging 36 3 System Power 37 3 1 Power Supply Configurations...

Page 6: ...tem Throttling CLST 50 3 7 Smart Ride Through SmaRT 51 3 8 Server Board Power Connectors 51 3 8 1 Power Supply Module Card Edge Connector 51 3 8 2 Optional 12 V Power Connectors for High Power Add in...

Page 7: ...92 7 4 3 Intel Virtual RAID on Chip Intel VROC for NVMe 96 7 4 4 NVMe Drive Population Rules for Intel VROC 97 7 5 Intel Integrated RAID Module Support 101 7 5 1 RAID Maintenance Free Backup Unit AXXR...

Page 8: ...s 124 Appendix B POST Code Diagnostic LED Decoder 125 B 1 Early POST Memory Initialization MRC Diagnostic Codes 126 B 2 BIOS POST Progress Codes 129 Appendix C POST Code Errors 132 C 1 POST Error Beep...

Page 9: ...el emboss dimensions 31 Figure 19 Pull out tab label emboss dimensions non storage models 32 Figure 20 Pull out tab label area dimensions storage models 32 Figure 21 System cable routing channels 33 F...

Page 10: ...Figure 59 2 x 2 5 hot swap backplane 83 Figure 60 2 5 Solid state drive SSD mounting option 85 Figure 61 Onboard storage support features 86 Figure 62 BIOS setup Mass Storage Controller Configuration...

Page 11: ...ard iPC A2UX8X4RISER 115 Figure 87 OCP module placement 116 Figure 88 Intel RMM4 Lite activation key placement 118 Figure 89 Dedicated management port 118 Figure 90 On board POST Diagnostic LEDs 125 F...

Page 12: ...Table 18 AC line surge transient performance 44 Table 18 Maximum Load Ratings 44 Table 19 Performance criteria 44 Table 20 Over current protection 1300 W power supply 45 Table 21 Over current protecti...

Page 13: ...connector pin out 79 Table 55 7 pin SATA cable connector pin out 83 Table 56 Power connector pin out 84 Table 57 I2C connector pin out 84 Table 58 SGPIO connector pin out 84 Table 59 SATA and sSATA co...

Page 14: ...Ie Riser Card iPN G94347 xxx 164 Table 88 Common Front Panel Board iPN H29366 xxx 164 Table 89 Storage System Model Mini Front Panel Board iPN G28538 xxx 164 Table 90 2U 8 x 3 5 Hot Swap Back Plane iP...

Page 15: ...00WF Product Family Power Budget Thermal Configuration Tool Public Intel Servers System BMC Firmware EPS for Intel Xeon processor Scalable Family Intel Confidential Intel Server System BIOS EPS for In...

Page 16: ...ery components that need adequate airflow to cool Intel ensures through its own chassis development and testing that when Intel server building blocks are used together the fully integrated system wil...

Page 17: ...See appropriate Intel System TPS for max supported TDP Memory 24 Total DIMM slots 12 DIMMs per processor o 6 Memory Channels per processor 2 DIMMs per Channel Registered DDR4 RDIMM Load Reduced DDR4...

Page 18: ...er 3 2U systems only PCIe 3 0 CPU 2 x12 2 slot riser card available Video Integrated 2D Video Controller 16MB of DDR4 Video Memory One DB 15 External Connector One 14 Pin Internal connector for option...

Page 19: ...ork interface connectors S2600WFT based systems only Dedicated RJ 45 server management NIC 3 USB 3 0 connectors on back panel 2 USB 3 0 connectors on front panel non storage system configurations only...

Page 20: ...hot swap drive bays 16 x 2 5 SAS SATA NVMe hot swap drive bays 24 x 2 5 SAS SATA NVMe swap drive bays 2 x 2 5 SATA SSD Back of Chassis Hot Swap Drive Bays accessory Option 2 x internal fixed mount 2 5...

Page 21: ...ct Family Technical Product Specification 21 2 1 System Features Overview Figure 1 System components overview Most 2U systems within this product family include the standard top cover shown in Figure...

Page 22: ...Intel Server System R2000WF Product Family Technical Product Specification 22 2 2 Server Board Architecture Figure 3 Server Board Architecture...

Page 23: ...Intel Server System R2000WF Product Family Technical Product Specification 23 Figure 4 S2600WFQ Server Board Architecture...

Page 24: ...provides a general overview of the server board identifying key feature and component locations For more information refer to Intel Server Board S2600WF Technical Product Specification Note Intel Serv...

Page 25: ...oduct Specification 25 The server board includes a number of LEDs to identify system status and or indicate a component fault Figure 6 and Figure 7 identify each diagnostic LED and their location Figu...

Page 26: ...Intel Server System R2000WF Product Family Technical Product Specification 26 Figure 7 Intel Light Guided Diagnostics DIMM fault LEDs Figure 8 System configuration and recovery jumpers...

Page 27: ...erver System R2000WF Product Family Technical Product Specification 27 2 4 Back Panel Features Figure 9 Back panel feature identification 2 5 Front Control Panel Options Figure 10 Front control panel...

Page 28: ...3 5 x 8 front drive bay configuration R2308WFxxxx Figure 12 3 5 x 12 front drive bay configuration R2312WFxxxx Figure 13 2 5 x 8 front drive bay configuration R2208WFxxxx Figure 14 2 5 x 16 front dri...

Page 29: ...and front drive bay by to support a locking front bezel Note Intel will not offer a front bezel accessory option OEMs looking to develop a locking front bezel can obtain necessary CAD files of the ch...

Page 30: ...Server System R2000WF Product Family Technical Product Specification 30 2 8 System Dimensional Data 2 8 1 Chassis Dimensions 2 5 Drive Bay Figure 17 Chassis dimensions 2 5 drive bay 3 5 89 mm 19 482...

Page 31: ...Intel Server System R2000WF Product Family Technical Product Specification 31 2 8 2 Label Emboss Dimensions Figure 18 Label emboss dimensions...

Page 32: ...Family Technical Product Specification 32 2 8 3 Pull Out Tab Label Emboss Dimensions Figure 19 Pull out tab label emboss dimensions non storage models Figure 20 Pull out tab label area dimensions sto...

Page 33: ...h chassis sidewall No cables should be routed directly in front of the system fans or through the center of the server board between the memory slots and CPU sockets The system fan assembly must be re...

Page 34: ...wo people or the use of a mechanical assist tool to install and align the server into the rack is highly recommended AXXELVRAIL Enhanced Value Rack Mount Rail Kit o 1U 2U 4U compatible o Tool less cha...

Page 35: ...11 msec Unpackaged Trapezoidal 25 g velocity change is based on packaged weight Packaged ISTA International Safe Transit Association Test Procedure 3A 2008 Vibration Unpackaged 5 Hz to 500 Hz 2 20 g R...

Page 36: ...hat allows the package to meet the ISTA Test Procedure 3A 2008 limits See the Intel Server System R2000WF Product Family System Integration and Service Guide for complete packaging assembly instructio...

Page 37: ...available maybe less than twice the rated power of the installed power supply modules due to the amount of heat produced with both supplies providing peak power Should system thermal levels exceed pro...

Page 38: ...provided at three different load levels 100 50 and 20 The AC power supply efficiency is tested over an AC input voltage range of 115 VAC to 220 VAC Table 6 1100 Watt AC power supply efficiency 80 Plus...

Page 39: ...udes dual in line 40 mm fans with one mounted inside the enclosure and the other extending outside the enclosure Note The second fan protrudes from the back of the power supply bay making the total le...

Page 40: ...1300W AC power supply module mechanical drawing 74 mm FCI 2x25 card edge connector 10035388 102 A25 A1 B25 B1 2 mm Retention latch Airflow direction 8 5 mm 39 mm Dual 40x40x28 mm fans 11 mm 185 mm 213...

Page 41: ...perage Rating 13 A Voltage Rating 125 V Figure 26 AC power cord specification Figure 27 DC power cord specification Table 10 DC power cable connector pin out Pin Definition 1 Return 2 Safety Ground 3...

Page 42: ...Parameter MIN Rated VMAX Startup VAC Power Off VAC Voltage 110 90 Vrms 100 127 Vrms 140 Vrms 85VAC 4VAC 74VAC 5VAC Voltage 220 180 Vrms 200 240 Vrms 264 Vrms Frequency 47 Hz 50 60 63 Hz Maximum input...

Page 43: ...o not cause the AC fuse to blow unless a component in the power supply has failed This includes DC output load short conditions 3 3 6 AC Inrush AC line inrush current does not exceed 55 A peak 1100 W...

Page 44: ...el standards please request a copy of the Intel Environmental Standards Handbook Table 20 Performance criteria Level Description A The apparatus continues to operate as intended No degradation of perf...

Page 45: ...the power supply s main outputs to shut down If the power supply latches off due to a protection circuit tripping an AC cycle OFF for 15 seconds and a PSON cycle HIGH for one second reset the power su...

Page 46: ...mperature warning threshold level 3 3 17 Power Supply Status LED There is a single bi color LED to indicate power supply status The LED operation is defined in Table 25 Table 25 LED indicators Power S...

Page 47: ...less the power supply must meet dynamic voltage regulation requirements for every rated load condition A DC line dropout of 0 2 msec or less shall not cause tripping of control signals or protection c...

Page 48: ...standard and performance criteria A defined in Annex B of CISPR 24 Limits shall comply with those specified in the Intel Environmental Standards Handbook Additionally the power supply must comply with...

Page 49: ...er usage efficiency when system loads are such that both power supplies are not needed When the power subsystem is in cold redundant mode only the needed power supply to support the best power deliver...

Page 50: ...er supply s role in cold redundancy and to turn on off cold redundancy To allow for equal loading over the life time of installed power supplies the BMC shall schedule a rolling re configuration of in...

Page 51: ...dule Card Edge Connector Each power supply module has a single 2x25 card edge output connection that plugs directly into a matching slot connector on the server board The connector provides both power...

Page 52: ...scription P12V 3 1 GND P12V 4 2 GND Figure 28 Power cable for the OPT_12V The power cable for the OPT_12V_PWR connectors shown in Figure 28 is included in the two slot riser card accessory kit iPC A2U...

Page 53: ...e peripheral options including Solid State Devices SSDs mounted to the top side of the air duct or to the rear mounted two drive backplane accessory option On the server board this connector is labele...

Page 54: ...m models within this 2U product family and are provided for reference purposes only The data was derived from actual wind tunnel test methods and measurements using fully configured worst case system...

Page 55: ...100 auto 189 0 100 100 194 2 55 auto 97 6 Table 42 System volumetric airflow Intel Server System R2208WFxxx 8 Drive Acc 16x2 5 System Fan PSU Fan Total Airflow CFM 100 auto 136 2 100 100 140 5 55 auto...

Page 56: ...t meet the following operating and configuration guidelines The system is designed to sustain operations at an ambient temperature of up to 35 C ASHRAE Class A2 with short term excursion based operati...

Page 57: ...tion Requirements System thermal requirements dictate that specific airflow be maintained over or between critical system components To ensure that proper air flow is achieved specific memory slots mu...

Page 58: ...ckets For multiple DIMMs per channel o For RDIMM LRDIMM 3DS RDIMM 3DS LRDIMM Always populate DIMMs with higher electrical loading in slot1 followed by slot 2 o NVM DIMMs must be populated in DIMM slot...

Page 59: ...fan domain has three states The sleep and boost states have fixed but configurable through OEM SDRs fan speeds associated with them The nominal state has a variable speed determined by the fan domain...

Page 60: ...removal of hot swap fans up to the number of redundant fans specified in the SDR in a fan configuration is a non critical failure and is reflected in the front panel status A fan failure or removal t...

Page 61: ...y requires the BMC to access temperature sensors on the individual memory DIMMs Additionally closed loop thermal throttling is only supported with buffered DIMMs 4 2 1 7 Thermal Sensor Input to Fan Sp...

Page 62: ...remaining system fans and manage other platform features to maintain system thermals Fan redundancy is lost if more than one system fan is in a failed state The server board is capable of supporting...

Page 63: ...hot swappable Each fan is blind mated to a matching 6 pin connector located on the server board Each fan is designed for tool less insertion and extraction from the fan assembly Each fan has a tachome...

Page 64: ...e by these management features The FRUSDR utility must be run as part of the initial platform integration process before it is deployed into a live operating environment Once the initial FRU and SDR d...

Page 65: ...m integrator to conduct appropriate system testing on server systems configured with a non Intel GPGPU card to ensure reliable operation For non Intel GPGPU cards listed on Intel s tested hardware and...

Page 66: ...wer cable are included in accessory kit A2UL16RISER2 Configuration Note An add in card that requires additional 12 V power and is installed in Riser Slot 1 must have its AUX 12 V power connector locat...

Page 67: ...it AWFCOPRODUCTAD A system configured with the contents of accessory kits AWFCOPRODUCTAD and AWFCOPRODUCTBKT and an Intel Xeon Phi card can also support the following additional PCIe add in card confi...

Page 68: ...orted A total system power budget should be calculated to determine if the power draw of the desired system configuration meets the power limits of the installed power supplies A power budget tool for...

Page 69: ...2 5 hot swap SSDs Up to two Internal fixed mount SSDs in all system models Up to two server board mounted M 2 PCIe SATA SSDs Support for different storage and peripheral options vary depending on the...

Page 70: ...device bracket Figure 42 3 5 drive bay 8 drive configuration Figure 43 3 5 drive bay 12 drive configuration Note Drive numbering in the system illustrations is for general reference only Actual drive...

Page 71: ...to assist with drive extraction and drive insertion Figure 44 Drive carrier removal Note To ensure proper system air flow requirements all front drive bays must be populated with a drive carrier Drive...

Page 72: ...49 Drive status LED states Amber LED State Drive Status Off No access and no fault Solid on Hard drive fault has occurred 1 Hz blinking RAID rebuild in progress 2 Hz blinking Locate identify Table 50...

Page 73: ...backplane options Appropriate power cables to support any given backplane option are included with the given system model or given backplane accessory kit For the HSBP power connector pin out see Tab...

Page 74: ...lacement options Backplanes include the following features 12 Gb SAS and 6 Gb SAS SATA or slower support Drive interface connectors o 29 pin SFF 8680 SATA SAS only o 68 pin SFF 8639 SATA SAS NVMe NVMe...

Page 75: ...has a master slave I2C connection to the server board BMC The microcontroller is not an IPMB compliant device The BMC generates SEL events by monitoring registers on the HSBP microcontroller for DRIV...

Page 76: ...en backplanes with connector A used on the first board and connector D used on the second board extending the SMBus to each installed backplane Table 52 I2C cable connector pin out Pin Signal 1 SMB_3V...

Page 77: ...d to the appropriate backplane OCuLink connector from any of the following PCIe signal sources Available onboard PCIe OCuLink connectors on the server board Optional PCIe 4 or 8 Port Switch Add in Car...

Page 78: ...onnectors for drives 0 3 Cables can be routed from matching connectors on the server board from installed add in SAS SATA RAID cards or from optionally installed SAS expander cards for drive configura...

Page 79: ...e 8 drive backplane have support for the following drive form factors 3 5 hard drives 2 5 SSDs using the included drive blanks as a drive bracket Note Due to degraded performance and reliability conce...

Page 80: ...rive Hot Swap Backplane Overview This section applies to the 12 x 3 5 drive hot swap backplane iPC F2U12X35S3PH 2U server systems that support the 12 drive backplane have support for the following dri...

Page 81: ...supplying power to the backplane Power is routed to the backplane via a power cable harness from the server board I2C cable connectors connector E The backplane includes a 1x5 cable connector used as...

Page 82: ...system models utilizing a maximum number of front and rear drive storage devices 12 x 3 5 or 24 x 2 5 in the front and 2 x 2 5 in the back Because of thermal limits in this area of the chassis the re...

Page 83: ...includes two hot swap capable SATA drive connectors 7 pin SATA cable connectors The backplane includes two 7 pin connectors capable of supporting a SATA interface The following table defines the pin o...

Page 84: ...used as a communication path to the onboard BMC The following table defines the pin out for this connector Table 58 I2C connector pin out Pin Signal 1 SMB_3V3SB_DAT 2 GND 3 SMB_3V3SB_CLK 4 SMB_ADD0 5...

Page 85: ...C The test system was based on the system models utilizing a maximum number of front and rear drive storage devices 12 x 3 5 or 24 x 2 5 in the front and 2 x 2 5 in the back Higher SSD power and ther...

Page 86: ...he AHCI sSATA controller provides support for up to 4 SATA ports on the server board Two ports accessed via two white single port 7 pin connectors labeled sSATA 4 and sSATA 5 on the server board Two p...

Page 87: ...Supported Staggered Spin Up Enables the host the ability to spin up hard drives sequentially to prevent power load problems on boot Supported Supported Supported Command Completion Coalescing Reduces...

Page 88: ...For the onboard SATA controller staggered spin up is an option AHCI HDD Staggered Spin Up in the Mass Storage Controller Configuration screen found in the BIOS setup utility 7 2 Onboard SATA Software...

Page 89: ...ree SATA drives needed to support RAID level 5 At least four SATA drives needed to support RAID level 10 NVMe SSDs and SATA drives must not be mixed within a single RAID volume With Intel RSTe softwar...

Page 90: ...ber of spans Optional support for RAID Level 5 o Enabled with the addition of an optionally installed ESRT2 SATA RAID 5 Upgrade Key iPN RKSATA4R5 Figure 63 ESRT2 SATA RAID 5 upgrade key o RAID 5 Uses...

Page 91: ...from embedded RAID options for server board mounted M 2 SSDs is defined as follows Neither Intel ESRT2 nor Intel RSTe have RAID support for PCIe M 2 SSDs when installed to the M 2 connectors on the se...

Page 92: ...6 retimer add in card accessory kit iPC AXXP3RTX16040 Intel Integrated RAID Modules with tri mode support 7 4 1 Onboard PCIe OCuLink Connectors The server board provides four 4 onboard PCIe OCuLink co...

Page 93: ...Does not support NTB Quick Data Tech Intel Omni Path Architecture or SR IOV Correctable errors do not bring down the system Intel VMD only manages devices on PCIe lanes routed directly from the proce...

Page 94: ...Riser Slot 1 Port 1D x4 Riser Slot 1 Port 2A x4 Chipset PCH uplink Port 2A x4 Riser Slot 2 Port 2B x4 Chipset PCH uplink Port 2B x4 Riser Slot 2 Port 2C x4 Chipset PCH uplink Port 2C x4 Riser Slot 2...

Page 95: ...uct Specification 95 In BIOS setup the Intel VMD support menu can be found under the following BIOS setup menu Advanced PCI Configuration Volume Management Device Figure 67 VMD support disabled in BIO...

Page 96: ...hardware that allows recovery from a double fault Isolated storage devices from OS for error handling Protected R5 data from OS crash Boot from RAID volumes based on NVMe SSDs within a single Intel VM...

Page 97: ...Drive Population Rules for Intel VROC In order to support NVMe RAID and NVMe Management features the optional Intel VROC Key must be installed on to the server board With the Intel VROC key installed...

Page 98: ...e to two different PCIe sources the defined population rules for each PCIe source are applied to the drive set connected to it 7 4 4 1 Onboard PCIe OCuLink Connectors and or Intel Tri mode RAID module...

Page 99: ...ctor 1 cannot be populated with a SAS SATA drive The same rule applies to ALL other drive pairs on the backplane The following illustrations identify supported and unsupported drive populations associ...

Page 100: ...ector of the given set drive connectors 0 or 4 Additional NVMe drives within the drive set must be populated in sequential order with no gaps between drive connectors Combining NVMe drives and SAS SAT...

Page 101: ...Intel and third party PCIe add in 12 Gb RAID adapters which can be installed in available PCIe add in cards slots For system configurations with limited add in card slot availability an optional Inte...

Page 102: ...ic connector 7 5 1 RAID Maintenance Free Backup Unit AXXRMFBUx Support The 2U system provides mounting plate options to support the concurrent installation of up to five possible RAID Maintenance Free...

Page 103: ...ote The two RMFBU node mounting plates cannot be installed if a full length PCIe add in card is installed in the adjacent riser card or if the Intel Xeon Phi shipping bracket is installed in the syste...

Page 104: ...y Technical Product Specification 104 Figure 75 SAS expander card installation In the 2U 12x3 5 system configuration the SAS expander must be installed in any available PCIe add in slot Intel makes av...

Page 105: ...m expander to RAID card cables PCI brackets for low profile and full height iPC RES3TV360 Intel RAID Expander RES3TV360 SAS 3 0 12 Gb s expander featuring 6 Gbps data aggregation for 12 Gbps data tran...

Page 106: ...uct Specification 106 Figure 77 12 GB internal 36 Port Intel RAID Expander Card RES3TV360 connector identification See the Intel Server S2600WF Product Family Configuration Guide for SAS cabling requi...

Page 107: ...the front of the system When BIOS detects that a monitor is attached to the front video connector it disables the video signals routed to the on board video connector on the back of the system Video r...

Page 108: ...a given issue where a memory download is necessary to help determine the cause of the problem To prevent an inadvertent system halt the actual NMI button is located behind the front control panel fac...

Page 109: ...Ctrl sensors Power supply predictive failure occurred while redundant power supply configuration was present Unable to use all of the installed memory more than 1 DIMM installed Correctable Errors ove...

Page 110: ...ical o Unable to synchronize processor frequency o Unable to synchronize QPI link frequency Uncorrectable memory error in a non redundant mode Power sleep button Toggles the system power on and off Th...

Page 111: ...he riser card slots are specifically designed to support riser cards only Attempting to install a PCIe add in card directly into a riser card slot on the server board may damage the server board the a...

Page 112: ...nd 2D x8 elec x16 mech N A Bottom CPU 2 Ports 1A and 1B x8 elec x8 mech CPU 2 Ports 1A and 1B x8 elec x8 mech Table 69 Riser slot 3 PCIe root port mapping PCIe Slot 2U Low Profile Riser Card iPC A2UX8...

Page 113: ...slot Two card guide brackets on the air duct provide support for full height full length add in cards when installed in either the middle or top add in card slots of each installed riser card assembly...

Page 114: ...2 Riser Card Options Several multi slot PCI riser card options are available for this server product family Available riser cards for riser slots 1 and 2 are common between the two slots 9 2 1 Three...

Page 115: ...upport up to two additional PCIe add in card slots for 2U server configurations The available riser card option is designed to support low profile add in cards only Figure 86 Low profile riser card iP...

Page 116: ...Project OCP specification The OCP compatible modules are mounted to a high density 120 pin connector on the server board labeled OCP_IO_Module Figure 87 OCP module placement Table 73 OCP Compatible I...

Page 117: ...mpts to access the Intel RMM4 Lite If the attempt to access Intel RMM4 Lite is successful then the BMC activates the advanced features The following table identifies both Basic and Advanced server man...

Page 118: ...ed Figure 89 Dedicated management port 11 2 Embedded Web Server BMC base manageability provides an embedded web server and an OEM customizable web GUI which exposes the manageability features of the B...

Page 119: ...ay configuration of various IPMI over LAN parameters for both IPV4 and IPV6 Display configuration of alerts SNMP and SMTP Display system asset information for the product board and chassis Display BMC...

Page 120: ...Features of the RMM4 lite enablement key are KVM redirection from either the dedicated management NIC or the server board NICs used for management traffic up to two KVM sessions Automatically senses v...

Page 121: ...managed host system the browser must include a Java Runtime Environment plug in If the browser has no Java support such as with a small handheld device the user can maintain the remote host system us...

Page 122: ...rive or a USB flash disk as a remote device to the server Once mounted the remote device appears just like a local device to the server allowing system administrators or users to install software incl...

Page 123: ...th the virtual IDE and virtual floppy are presented as bootable devices It is not possible to present only a single mounted device type to the system BIOS 11 3 8 1 Availability The default inactivity...

Page 124: ...and memory channels On the back edge of the server board are eight diagnostic LEDs that display a sequence of amber POST codes during the boot process If the server board hangs during POST the LEDs di...

Page 125: ...green and four amber The POST codes are divided into two nibbles an upper nibble and a lower nibble The upper nibble bits are represented by amber diagnostic LEDs and the lower nibble bits are repres...

Page 126: ...1h 1 0 1 1 0 0 0 1 Set DDR4 frequency N A B2h 1 0 1 1 0 0 1 0 Gather remaining SPD data N A B3h 1 0 1 1 0 0 1 1 Program registers on the memory controller level N A B4h 1 0 1 1 0 1 0 0 Evaluate RAS mo...

Page 127: ...ed Fatal MRC error halts do NOT change the state of the system status LED and they do NOT get logged as SEL events The following table lists all MRC fatal errors that are displayed to the diagnostic L...

Page 128: ...E9h 1 1 1 0 1 0 0 1 Memory is locked by Intel Trusted Execution Technology and is inaccessible EAh 1 1 1 0 1 0 1 0 DDR4 Channel Training Error 01h Error on read DQ DQS Data Data Strobe init 02h Error...

Page 129: ...ect infor such as SBSP boot mode reset type etc A3h 1 0 1 0 0 0 1 1 Setup minimum path between SBSP and other sockets A6h 1 0 1 0 0 1 1 0 Sync up with PBSPs A7h 1 0 1 0 0 1 1 1 Topology discovery and...

Page 130: ...e Media Detect 7Eh 0 1 1 1 1 1 1 0 DXE Removable Media Detected 90h 1 0 0 1 0 0 0 0 DXE BDS started 91h 1 0 0 1 0 0 0 1 DXE BDS connect drivers 92h 1 0 0 1 0 0 1 0 DXE PCI bus begin 93h 1 0 0 1 0 0 1...

Page 131: ...DXE Legacy Option ROM init B3h 1 0 1 1 0 0 1 1 DXE Reset system B4h 1 0 1 1 0 1 0 0 DXE USB Hot plug B5h 1 0 1 1 0 1 0 1 DXE PCI BUS Hot plug B8h 1 0 1 1 1 0 0 0 PWRBTN Shutdown B9h 1 0 1 1 1 0 0 1 S...

Page 132: ...system continues booting in a degraded state The user may want to replace the erroneous unit The POST Error Pause option setting in the BIOS setup does not have any effect on this error Major An erro...

Page 133: ...Intel Server System R2000WF Product Family Technical Product Specification 133 Table 80 POST Error Messages and Handling...

Page 134: ...Password clear jumper is Set Recommend to remind user to install BIOS password as BIOS admin password is the master keys for several BIOS security features Major 8130 Processor 01 disabled Major 8131...

Page 135: ...CPU1_DIMM_F1 please remove the disabled DIMM Major 8530 Memory failed test initialization CPU1_DIMM_F2 please remove the disabled DIMM Major 8531 Memory failed test initialization CPU1_DIMM_F3 please...

Page 136: ...he disabled DIMM Major 8553 Memory disabled CPU1_DIMM_G2 please remove the disabled DIMM Major 8554 Memory disabled CPU1_DIMM_G3 please remove the disabled DIMM Major 8555 Memory disabled CPU1_DIMM_H1...

Page 137: ...y encountered a Serial Presence Detection SPD failure CPU1_DIMM_F1 Major 8570 Memory encountered a Serial Presence Detection SPD failure CPU1_DIMM_F2 Major 8571 Memory encountered a Serial Presence De...

Page 138: ...abled DIMM Major 85CB Memory failed test initialization CPU2_DIMM_G2 please remove the disabled DIMM Major 85CC Memory failed test initialization CPU2_DIMM_G3 please remove the disabled DIMM Major 85C...

Page 139: ...ed a Serial Presence Detection SPD failure CPU2_DIMM_F3 Major 85EA Memory encountered a Serial Presence Detection SPD failure CPU2_DIMM_G1 Major 85EB Memory encountered a Serial Presence Detection SPD...

Page 140: ...4 Recovery failed N A Recovery has failed This typically happens so quickly after recovery is initiated that it sounds like a 2 4 beep code The Integrated BMC may generate beep codes upon detection o...

Page 141: ...ot is limited to add in cards that have air flow requirements of 100 LFM or less See add in card specs for air flow requirements 6 For ASHRAE Class 3 and Class 4 support the following power supply mar...

Page 142: ...83 Thermal configuration table for system in normal operating mode Thermal Configuration Matrix Normal Operating Mode Full Support without limitation 4 5 Cell with number Conditional support with limi...

Page 143: ...Xeon Platinum 8164_26C 3 Intel Xeon Platinum 8160_24C 3 Intel Xeon Gold 6148_20C 3 Intel Xeon Gold 6136_12C Intel Xeon Platinum 8158_12C Intel Xeon Gold 6142_16C 3 140 W Intel Xeon Gold 6132_14C 3 3...

Page 144: ...See Note 23 RDIMM 2Rx8 1Rx4 1Rx8 RDIMM DRx4 LRDIMM QRx4 DDP 3 3 3 Add in Cards See Note 5 Riser 1 Bottom Slot 1U riser and 2U riser Riser 1 Middle Slot 2U riser Riser 1 Top Slot 2U riser Riser 2 Bott...

Page 145: ...CIe SSD AIC FF DC P3700 P3500 See Note 8 1600GB 2TB 8 8 800GB 8 8 600GB 8 8 400GB 8 8 200GB Intel Xeon Phi See Notes 7 10 Active Cooling up to 300W Active Cooling up to 225W Intel Xeon Phi w Passive C...

Page 146: ...2 A3 A4 27C A2 A3 A4 Max Ambient 27 C 1 35 C 40 C 45 C 27 C 1 35 C 40 C 45 C 27 C 1 35 C 40 C 45 C Altitude 900 900 900 900 900 900 900 900 900 900 900 900 PS See Notes 2 6 1300W AC 18 19 25 20 26 19...

Page 147: ...6126F_12C 130 W Intel Xeon Gold 6134_8C 125 W Intel Xeon Gold 6138_20C 3 Intel Xeon Gold 6130_16C 3 Intel Xeon Platinum 8153_16C 3 Intel Xeon Gold 6126_12C 115 W Intel Xeon Gold 6128_6C 113 W Intel Xe...

Page 148: ...lot 2U riser 3rd PCI Riser Riser 3 Bottom Slot 5 5 5 5 5 Riser 3 Top Slot 5 5 5 5 5 SAS and OCP Modules See Note 4 Intel Integrated RAID Modules Mezzanine cards 16 port tri mode mezzanine Dual 10GBase...

Page 149: ...7 10 Active Cooling up to 300W Active Cooling up to 225W Intel Xeon Phi w Passive Cooling up to 225W Intel Xeon Phi w Passive Cooling up to 245W 7 7 7 7 7 7 7 Intel Xeon Phi w Passive Cooling up to 3...

Page 150: ...A4 27C A2 A3 A4 27C A2 A3 A4 Max Ambient 27 C 1 35 C 40 C 45 C 27 C 1 35 C 40 C 45 C 27 C 1 35 C 40 C 45 C 27 C 1 35 C 40 C 45 C Altitude 900 900 900 900 900 900 900 900 900 900 900 900 900 900 900 9...

Page 151: ...24 24 24 Intel Xeon Gold 6126F_12C 24 24 24 24 24 24 24 24 130 W Intel Xeon Gold 6134_8C 24 24 24 24 24 24 125 W Intel Xeon Gold 6138_20C 24 24 24 24 24 24 Intel Xeon Gold 6130_16C 24 24 24 24 24 24 I...

Page 152: ...ot 2U riser 5 5 5 5 5 5 Riser 2 Top Slot 2U riser 5 5 5 5 5 5 3rd PCI Riser Riser 3 Bottom Slot 5 5 5 5 5 5 Riser 3 Top Slot 5 5 5 5 5 5 SAS and OCP Modules See Note 4 Intel Integrated RAID Modules Me...

Page 153: ...6 16 16 M 2 Light Workload See Note 15 Intel 120G and 80G SATA 14 14 14 14 14 14 14 14 14 14 Non Intel M 2 16 16 16 16 16 16 16 16 16 16 Thermal Configuration Matrix Fan Fail Operating Mode Full Suppo...

Page 154: ...24 Intel Xeon Gold 6142F_16C 24 24 24 24 24 150 W Intel Xeon Platinum 8164_26C 24 24 24 24 24 24 Intel Xeon Platinum 8160_24C 24 24 24 24 24 24 Intel Xeon Gold 6148_20C 24 24 24 24 24 24 Intel Xeon G...

Page 155: ...10_8C 24 Intel Xeon Silver 4108 _8C 24 Intel Xeon Bronze 3106 _8C 24 Intel Xeon Bronze 3104_6C 24 Intel Xeon Silver 4112_4C 24 Memory Type See Note 23 RDIMM 2Rx8 1Rx4 1Rx8 RDIMM DRx4 LRDIMM QRx4 DDP 3...

Page 156: ...e SSD AIC FF DC P3700 P3500 See Note 8 1600GB 2TB 8 8 8 8 800GB 8 8 8 8 600GB 8 8 8 8 400GB 8 8 8 8 200GB 8 8 Intel Xeon Phi See Notes 7 10 Active Cooling up to 300W Active Cooling up to 225W Intel Xe...

Page 157: ...Intel Server System R2000WF Product Family Technical Product Specification Intel Confidential 157...

Page 158: ...Intel Server System R2000WF Product Family Technical Product Specification 158 Intel Confidential Appendix E System Cable Routing Diagrams Figure 91 R2308WFxxx system cable routing diagram...

Page 159: ...Intel Server System R2000WF Product Family Technical Product Specification Intel Confidential 159 Figure 92 R2208WFxxx system cable routing diagram...

Page 160: ...Intel Server System R2000WF Product Family Technical Product Specification 160 Intel Confidential Figure 93 R2312WFxxx system cable routing diagram...

Page 161: ...Intel Server System R2000WF Product Family Technical Product Specification Intel Confidential 161 Figure 94 R2208WFxxx 8 drives system cable routing diagram...

Page 162: ...Intel Server System R2000WF Product Family Technical Product Specification 162 Intel Confidential Figure 95 R2224WFxxx system cable routing diagram...

Page 163: ...er board silkscreen User Data The flash components on the server boards do not store user data from the operating system No operating system level data is retained in any listed components after AC po...

Page 164: ...Slot 3 Low Profile PCIe Riser Card iPN G94347 xxx Component Type Size Board Location User Data Name Non Volatile 256x8 U2 Yes FRU Table 89 Common Front Panel Board iPN H29366 xxx Component Type Size...

Page 165: ...wap Back Plane iPN G97166 xxx Component Type Size Board Location User Data Name Non Volatile 16384x8 U3A2 Yes PSOC Microcontroller FRU Non Volatile N A U3A1 No CPLD Code Table 95 Intel 2U 2 x 2 5 Rear...

Page 166: ...Feet per Minute Air Flow measurement LPC Low pin Count LRDIMM Load Reduced DIMM LSB Least Significant Bit MSB Most Significant Bit MTBF Mean Time Between Failure NIC Network Interface Card NMI Non ma...

Page 167: ...y Technical Product Specification Intel Confidential 167 TPS Technical Product Specification Intel TXT Intel Trusted Execution Technology for servers VLSI Very Large Scale Integration VSB Voltage Stan...

Reviews: