Intel® Server System M20NTP1UR - System Integration and Service Guide
74
6.11
Intel® VROC 7.5 (VMD NVMe* RAID) Key Replacement
This section provides instructions for the replacement of an Intel® VROC Key in the system.
Required Tools and Supplies
•
Intel® VROC 7.5 Key – iPCs:
VROCSTANMOD
or
VROCPREMMOD
or
VROCISSDMOD
•
Anti-static wrist strap and conductive workbench pad (recommended)
1.
Power off the system and disconnect all cable from the back of the system.
2.
Remove the system top cover (see
Section 6.1.1
3.
Remove the system air duct (see
Section 6.2.1
4.
Remove the riser card assembly (see
5.
Carefully remove the Intel® VROC Key from the server board (See
Figure 92. Intel® VROC Key Removal
•
Using the key pull tab, pull the key up until it disengages from the connector.
6.
Locate and unpack the new Intel® VROC Key
7.
Install the Intel® VROC Key to the connector on the server board (see
Figure 93. Intel® VROC Key Installation
•
Position the Intel® VROC Key over the connector and ensure the alignment features of the key and
connector match.
•
Place the Intel® VROC 7.5 Key onto the pins of the connector and press it down until it is securely
in place
Summary of Contents for M20NTP1UR
Page 2: ...2 This page intentionally left blank...
Page 101: ...Intel Server System M20NTP1UR System Integration and Service Guide 101 1 2 3 4 5...
Page 102: ...Intel Server System M20NTP1UR System Integration and Service Guide 102 1 2 3 4 5 6 1 2 3...
Page 103: ...Intel Server System M20NTP1UR System Integration and Service Guide 103 1 2 3 4 5...
Page 112: ...Intel Server System M20NTP1UR System Integration and Service Guide 112 1 2 3 4 5 ESD 6 1 2 3...
Page 113: ...Intel Server System M20NTP1UR System Integration and Service Guide 113 1 2 3 4 5...