Configuration Software and Utilities
Console Redirection Submenu
Feature
Choices
Description
COM Port Address
Disabled
3F8
2F8
3E8
When enabled, console redirection uses the I/O port specified.
3F8 - typically is COM1
2F8 - typically is COM2
All keyboard/mouse and video will be directed to this port. This
is designed to be used only under DOS in text mode.
IRQ #
N/A
This field is informational only.
Baud Rate
9600
19.2k
38.4k
115.2k
When console redirection is enabled, specifies the baud rate to
be used.
Flow Control
No Flow Control
CTS/RTS
XON/XOFF
CTS/RTS + CD
None disallows flow control.
CTS/RTS is hardware-flow control.
XON/XOFF is software-flow control.
CTS/RTS +CD is hardware plus carrier-detect flow control.
Summary of Contents for L440GX+