Intel® Server D50TNP Family Integration and Service Guide
175
7.14
Intel® Virtual RAID on CPU (Intel® VROC) Upgrade Key Replacement
This section provides instructions to replace an Intel® VROC Key in the system. Refer to the
Intel® Server
D50TNP Family Configuration Guide
for available options.
Required Tools and Supplies
•
Anti-static wrist strap and ESD safe workbench (recommended)
1.
Remove the module from the chassis (see
Section 7.1.1
2.
For air-cooled modules, remove the air duct (see Section
).
3.
Remove riser card assemblies (see
Section 7.8
).
Figure 258. Removing the Intel® VROC Upgrade Key
4.
Locate the Intel® VROC upgrade key near the right edge of the server board.
5.
Using the key pull tab, carefully pull up on the key until it disengages from the connector.
Figure 259. Installing the Intel® VROC Upgrade Key
6.
Remove the Intel® VROC upgrade key from its packaging.
7.
Place the key over the connector and confirm that the orientation of the key matches that of the
connector.
8.
Press the key down onto the connector until it locks into place.
7.15
Trusted Power Module (TPM) Replacement
Required Tools and Supplies
•
Anti-static wrist strap and conductive workbench pad (recommended)
•
Phillips* head screwdriver #1
1.
Remove the module from the chassis (see
Section 7.1.1
2.
For air-cooled modules, remove the air duct (see Section
).
3.
Remove riser card assemblies (see
Section 7.8