![Intel Application Accelerator RAID Edition User Manual Download Page 72](http://html.mh-extra.com/html/intel/application-accelerator-raid-edition/application-accelerator-raid-edition_user-manual_2073399072.webp)
Intel Application Accelerator RAID Edition Utility
R
72
User's Manual
21.4.1
Status Entries for Physical Disk Parameters:
Status
Indicates the health of the disk
Normal
Disk is present and functioning as expected
Error Occurred
Disk has exceeded its unrecoverable threshold.
Disk will continue to be accessed if it’s a member
of a RAID 0 volume.
SMART Event
Disk has exceeded its recoverable error
threshold and is at risk of failure.
Missing
Disk is not present.
Incompatible Version
Disk has RAID meta-data on it but its version is
incompatible with the current version of RAID
software. Updated version might be needed in
order to resolve
21.4.2
Status Entries for Volume Parameters:
Status
Indicates the health of the RAID volume
Normal
Volume data is fully accessible to host
Failed
One or more disks are missing or have failed,
and the volume will complete all I/O requests
with a failing status.
Migrating
A RAID volume topology (RAID level, strip size,
capacity, etc.) is changing
21.5
Generate and View a Report using the Intel
Application Accelerator RAID Edition Utility
The Intel Application Accelerator RAID Edition utility allows you to generate and view a report.
Everything that appears for each device in your system (except for the Serial #'s), can be
generated into a report. This information can be very helpful if you need assistance from Intel
Customer Support.
To generate and view a report, simply arrow up and click on 'File' (located at the top left of the
window), arrow down to ‘Report’ and then over to the right and click on 'View' as illustrated in
the following example:
Summary of Contents for Application Accelerator RAID Edition
Page 1: ...Intel Application Accelerator RAID Edition User s Manual Revision 1 1 July 2003 ...
Page 8: ...R 8 User s Manual This page is intentionally left blank ...
Page 10: ...Scope of This Document R 10 User s Manual This page is intentionally left blank ...
Page 12: ...RAID Background R 12 User s Manual This page is intentionally left blank ...
Page 14: ...RAID 0 Striping R 14 User s Manual This page is intentionally left blank ...
Page 16: ...RAID 1 Mirroring R 16 User s Manual This page is intentionally left blank ...
Page 18: ...RAID Migration Feature R 18 User s Manual This page is intentionally left blank ...
Page 24: ...BIOS Importance Settings R 24 User s Manual This page is intentionally left blank ...
Page 40: ...Intel RAID Option ROM R 40 User s Manual This page is intentionally left blank ...
Page 52: ...Issues During Installation R 52 User s Manual This page is intentionally left blank ...