Model No: M150 Plus
Customer: INTEK Rev No: A
12
7.
BAND SELECTION:
M-150:
1) switch ON radio while pressing the UP key
2) display will show the current band ID code (blinking)
3) select band using the UP or DN keys
4) shortly press the DN key to confirm
5) display will show the selected band ID code for 2-3 seconds, then it will show the
channel number
M-760:
1) switch ON radio while pressing the EMG key
2) display will show the current band ID code (blinking)
3) select band using the UP or DN keys
4) shortly press the EMG key to confirm
5) display will show the selected band ID code for 2-3 seconds, then it will show the
channel number
6.0 Factory Setting of Band for Shipment
FACTORY SETTING
All radios must be shipped from factory set as follows :
BAND SETTING : EUROPEAN BANDS ONLY
RADIO SWITCH ON :
CE BAND
Step
Setting
Connection
Adjuster
Adjust for
1
Frequency adjustment
MIC : Receive Volume :
optional Squelch :
optional CH selector :
19 EU CH9 : off
Frequency counter
to dummy load
(Figure 1).
CT1
27.185MHz±300Hz
2
VCO Voltage
adjustment MIC :
Receive Volume :
optional Squelch :
optional CH selector :
1A CH9 : OFF
Connect DC
voltmeter between
R97, C112and
GND. (Figure 2).
L17
1V at RX.