Integra FIREBOY eco 144010 Operating Instructions Manual Download Page 16

FIREBOY eco - Operating instructions V07

Operation

16

INTEGRA Biosciences AG

Engl

ish

4

Operation

Purpo-

se

This chapter explains how to operate FIREBOY eco and switch between the
operating modes. In addition, the steps to be taken in the event of an error are
described.

4.1

Switching FIREBOY eco on and off

FIREBOY eco is a mains-dependent device. FIREBOY eco is switched on by
briefly pressing on the PUSH BUTTON. The green LED is illuminated, and the
device is ready for use. It is switched off by pressing the button for a longer
period of at least 2 seconds. 

C

AUTION

Risk of burns! Even after it is switched off, the device may still be hot. 

4.2

F

OOT

 

SWITCH

 operating mode

FIREBOY eco is ignited by activating the foot or benchtop switch. The flame
burns as long as the switch is depressed. 

4.3

C

ONTINUOUS

 operating mode via the PUSH BUTTON

Alternatively, FIREBOY eco can be ignited and also extinguished by pressing
the PUSH BUTTON. The maximum burning time is 60 min.

W

ARNING

Never let the burner burn unattended! 

Summary of Contents for FIREBOY eco 144010

Page 1: ...FIREBOY eco Operating instructions 144951_V07...

Page 2: ...dards for EU Safety requirements for electrical equipment for measurement control and laboratory use General requirements EN 61010 1 2010 Electrical equipment for measurement control and laboratory us...

Page 3: ...to the electricity supply 11 3 2 Connecting FIREBOY eco to the gas supply 11 3 3 Connecting the foot or benchtop switch 15 3 4 Removing and adding the burner head 15 3 5 Long burner head 15 Chapter 4...

Page 4: ...INTEGRA Biosciences AG These operating instructions have the part number 144951 the version is V07 They apply for firmware Version 1 n Manu facturer INTEGRA Biosciences AG INTEGRA Biosciences Corp CH...

Page 5: ...se operating instructions These operating instructions specifically advise of residual risks with the following symbols WARNING This safety symbol advises of hazards that could result in injury or dea...

Page 6: ...a manner not specified by INTEGRA Biosciences the protection provided by the FIREBOY eco may be impaired FIREBOY eco may not be altered in design or in any of its safety aspects If alterations are ma...

Page 7: ...ust be observed Please visit our website www integra biosciences com on a regular basis for up to date information regarding REACH classified chemicals contained in our products 1 4 2 General safety n...

Page 8: ...breaks are taken and after the work has been completed cleaning and repair work is being performed the adapter is being replaced 1 4 3 Restrictions for use The following uses of the FIREBOY eco are p...

Page 9: ...s fitted ex factory Nozzle N80 natural gas Adapter for gas hose inner diameter 10 mm Operating instructions CAUTION Verify the scope of delivery when unpacking the device and check for potential trans...

Page 10: ...head 7 Ignition electrode 8 Burner chamber with flame opening 9 Electrode of the flame monitor Rear view 10 Switch connection jack 11 Mains plug socket mains plug 12 Gas adapter opening for engaging...

Page 11: ...re 81 methane further alkanes and commercial butane propane gas mixture 65 10 butane 20 40 propane 3 2 1 Fitting the nozzle for the gas in use The P60 nozzle for butane propane gas is fitted ex factor...

Page 12: ...cks into position The adapter is now installed WARNING When replacing the adapters always switch off the device disconnect the mains plug and close off the gas supply Unscrew the brass screw 1 on the...

Page 13: ...used at an ambient temperature of 15 35 C see note in the cartridge instructions The connection of the CP 250 CV 300 Plus CV 470 and EXPRESS 444 cartridges is described in the enclosed instructions T...

Page 14: ...kwise in the ON direction The gas cartridge has been changed CAUTION Gas will begin to flow 3 2 5 Connecting to the central gas supply or to a gas cylinder Connect the tubing from the central supply o...

Page 15: ...stall the burner head place it on the device with the 3 contact pins and push it down vertically until it clicks into position The burner head is now reinstalled CAUTION Never carry the device by the...

Page 16: ...BUTTON The green LED is illuminated and the device is ready for use It is switched off by pressing the button for a longer period of at least 2 seconds CAUTION Risk of burns Even after it is switched...

Page 17: ...Every message must be confirmed by pressing the PUSH BUTTON The following table lists the possible errors and the recommended action for elimination In order to protect the burner chamber from contam...

Page 18: ...Prior to ignition process the contact pin on the burner head is not detected Burner head not added or not added correctly Add burner head Contact pin on burner head is contaminated Clean the contact p...

Page 19: ...ilable disinfecting or cleaning agents It can also be replaced with a new one see 7 1 Accessories on page 22 CAUTION Ignition and flame monitoring electrodes white ceramic posts only tolerate low mech...

Page 20: ...enance 20 INTEGRA Biosciences AG English 5 3 Disposal The FIREBOY eco device must not be disposed of with unsorted municipal waste Dispose of the FIREBOY eco in accordance with the laws and regulation...

Page 21: ...Hz Device Input 8 6 9 4 VDC 0 5 A max 5 W Materials Metallic Housing zinc Burner head stainless steel brass Display glass Base PBT polybutylene terephthalate PC polycarbonate Operating conditions Oper...

Page 22: ...Part No Gas cartridge adapter for 52 g butane cartridge e g Campingaz CV 360 144 050 Gas cartridge adapter for 250 g butane cartridge e g Campingaz CP 250 with safety stand and connecting hose 144 05...

Page 23: ...ead for continuous operation 144 306 Mains adapter Europe 230 VAC 156 631 Mains adapter UK 240 VAC 156 632 Mains adapter US 120 VAC 156 630 Mains adapter AU 240 VAC 156 633 Mains adapter JP 100 VAC 15...