![Intec Force 1 Instruction Manual Download Page 33](http://html1.mh-extra.com/html/intec/force-1/force-1_instruction-manual_2070478033.webp)
32
T
R
O
U
B
L
E
S
H
O
O
T
I
N
G
THE FORCE / 1
Troubleshooting Cont.
Problem
Likely Cause
Remedy
Agitator trips circuit
at main panel.
Blower trips circuit
breaker at power source.
Operator in attic keeps
getting shocked.
Low voltage. 99-104 VAC
Incorrect size extension cord.
Pushing down on material in
hopper.
Wet insulation material in
hopper.
Worn or frozen airlock
bearing.
Low voltage.
Incorrect extension cord.
Worn brushes in blower
motor.
Static electricity from
insulation.
FORCE/1 requires a
minimum of 20 amps @
115V.
Relocate power cord to a
dedicated 20 amp circuit.
For an additional 50’ run,
use 12/3 cord. For a 100’
run use 10/3 cord.
Do not push down on
insulation while filling
hopper.
Do not use wet material.
Disconnect electrical
power and remove wet
material.
Have bearing checked
and replaced by a
qualified technician.
Blower requires a
minimum of 20 amps @
115V. Use a dedicated
refrigerator outlet or
equivalent.
For an additional 50’ run,
use 12/3 cord. For a 100’
run use 10/3 cord.
Inspect blower brushes,
Brushes should not be
shorter than 3/8” overall
length. Replace Brushes if
they are less than 3/8” or
chipped.
Mix half-and-half solution
of water and fabric
softener. Mist into
insulation while loading
hopper. Note: excess
moisture will cause
jamming.
Note:
To clear all jams, turn machine upside down and follow the instructions printed
on the motor housing.
Summary of Contents for Force 1
Page 3: ...MACHINE INFORMATION 2...
Page 9: ...8 THE FORCE 1 Overview OVERVIEW...
Page 42: ...ELECTRICAL DRAWINGS 41 Electrical Wiring Diagram Electrical With Relay Mfg from 10 02 Present...
Page 45: ......
Page 48: ......