MAINTENANCE
28
THE FORCE/1
Maintenance, Cont.
BLOWER MAINTENANCE
Keeping the blower as clean as possible will avoid system
overheating. Overheating will cause lowered production, possible
system failure and shorten the expected life of your FORCE/1. Inspect
blower brushes every three months or 100 hours of use. Replace
brushes when they reach
1
⁄
4
inch or less in length. Change the brushes
before the brush stunt touches the commutator. When reassembling,
the lead wires must be isolated from the motor frame and any rotating
parts.
CLEANING
Use compressed air to blow out motor and intake of blower every 20-
30 hours of use to maximize blower impeller and motor life.
Blower Warranty Considerations.
The following blower abuse is
not covered by warranty:
Damage in shipment
Visible moisture damage such as rust
Rust or other corrosion on motor exterior
Dirty motor or dust buildup in impeller
Broken components, i.e. brushes, brush holder, etc.
User modification of blower, holes, etc.
User rewound armatures or fields
Evidence of user disassembly
Evidence of foreign object in fan end of motor