background image

TwinLock compact  

Manual

 

 
 
 

 

 

 

Version 1.06 

 
 

51 

 

7. Programming the System with the PC Software 
TwinComm 
 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
The following functions can be performed with the configuration software TwinComm. 
 

General settings 

  Silent alarm, alarm delay 

  TwinXT active 

  Automatic switching to daylight savings time  

  Quick unlocking code 

 

Four-eye-principle 

 

  Parallel code 

  Lock after bolt system contact query  

  Automatic locking with door switch 

  Quick unlocking code 

  System line 

  Battery warning limit 

 

Timer Programs 

  Alarm time delay 

  Time delay, release time 

 

Managing functions 

  Customer data 

  User data 

  Menu simulator and menu wizard 

 
 

 

TwinCard

Configuration

 -

Summary of Contents for TwinLock compact

Page 1: ...TwinLock compact Manual Version 1 06 1 TwinLock compact Manual EN 1300 M 106302 M 106301 G 106016 G 106015 Class 2 C ...

Page 2: ...ity nor any liability for incorrect information and their consequences Suggestions for improvements and comments are always welcome Trademarks and logos The use of a trademark or logo not shown below does not indicate that it is freely available for use INSYS is a registered trademark of INSYS MICROELECTRONICS GmbH Windows is a registered trademark of Microsoft Corporation Publisher INSYS MICROELE...

Page 3: ... MASTER responsible for the system configuration and administration For users we recommend the Quick Reference Guide The concise document contains all important information required for normal system operation in short form The document ASSEMBLY INSTRUCTIONS has been created to assist with the installation of the system This contains all information for the implementation of the TwinLock system ...

Page 4: ...STEM WITH THE CONTROL UNIT 29 6 1 REPROGRAMMING A MASTER CODE 30 6 2 REPROGRAMMING THE MANAGER CODE 31 6 3 PROGRAMMING AND REPROGRAMMING OF A USER CODE 32 6 4 DELETE A USER CODE 33 6 5 DISPLAY THE PROGRAMMED USER CODES 34 6 6 SETTING THE DATE TIME AND WEEKDAY 35 6 7 CODE LINKAGE PROGRAMMING FOUR EYE CODE 36 6 8 PROGRAM UNLOCKING TIME DELAY 37 6 9 PROGRAM OPENING DURESS FORCED SEQUENCE 38 6 10 PROG...

Page 5: ...TwinLock compact Manual Version 1 06 5 7 4 DISPLAY EVENT LOG 58 7 5 USER DATA MANAGEMENT 59 7 6 CUSTOMER DATA MANAGEMENT 60 8 TECHNICAL DATA 61 Revision History Support Hotline ...

Page 6: ...Diagram TwinLock compact 1 lock with 12 VDC power supply TwinXT optional TwinLock compact 2 locks with 12VDC power supply TwinXT optional 1 2 3 4 7 F 5 6 8 9 0 F TwinConnect TwinLock TwinXT 1 2 3 4 7 F 5 6 8 9 0 F TwinConnect TwinLock TwinXT TwinLock ...

Page 7: ...on the outside of the safe see assembly of the input unit and is used to control and operate the locking system code input programming etc as well as to arm or disarm a burglary alarm system using a physical code chip card 2 2 Lock TwinLock compact The locks are mounted within the secured area of the safe see assembly of locks The mnemonic codes are stored and evaluated inside the locks 2 3 Bus Di...

Page 8: ...y Basically a TwinXT can be connected to each lock in the system Consequently each lock can be specifically locked or released and each lock can have a bolt system contact 2 switching inputs release bolt system contact for lock 1 2 switching inputs release bolt system contact for lock 2 2 relay outputs status silent alarm 30V 1A Power supply 12 VDC Antitamper loop with tamper switch ...

Page 9: ... configuration Chip card for the system configuration and the event log In cooperation the with PC software TwinComm the configuration can be imported or exported and the log can be read out TwinCard language Chip card for the configuration of the system language German English Czech Portuguese TwinCard TwinComm Lizenzchipkarte for the TwinComm configuration Software ...

Page 10: ...m can be configured fast and conveniently using the program TwinComm in connection with the chip card reader of the configuration set and the chip card TwinCard configuration All settings and the event log can be displayed printed and saved Daten Import Konfiguration TwinLock TwinCard Configuration ...

Page 11: ...uence Parallel code Automatic lock with door switch Timer Functions Time delay Alarm sabotage delays Automatic switching to daylight savings time Service Functions Event log 768 events Import export of the configuration via chip card System language can be configured using the chip card Reset of the individual system components Query of the system component version System components login logout S...

Page 12: ...stly consequences Manager code There is one manager code 6 character code per lock The manager code is also called the system code The manager code has the authorization to program the settings and time functions It does not have any opening authorization though The manager code cannot be deleted or deactivated ATTENTION The code 1 1 1 1 1 1 is pre programmed as the works code for the system code ...

Page 13: ...d sequence When a opening duress is activated the locks can only be opened in a certain order sequence lock 01 02 When locking the system the sequence is reversed The system is only unlocked and accessible for configuration and service after all locks have been opened Automatic lock with door switch The system can be locked automatically using a door switch or a bolt system contact which is either...

Page 14: ...acts exactly like for the normal opening procedure for the user and the intimidator but at the same time a silent alarm signal is sent to the BAS Furthermore an individual opening time delay may be defined for the case of an alarm The lock can only be opened after the set waiting period has expired see also timer programs 3 2 2 The defined release time of the normal time delay is used as release t...

Page 15: ...is performed by the system manager A user can be assigned a quick unlocking code function to bypass this program Alarm sabotage delays When the unlocking code was entered incorrectly 4 times a time delay of 1 minute starts For each further attempt with a wrong code the waiting period is extended by 1 minute up to a maximum of 15 minutes When a silent alarm is triggered a waiting period with a set ...

Page 16: ...mport export An entire configuration profile can be swapped out to the chip card Twin Card Configuration This profile can then be edited with the PC software TwinComm and reimported or saved The above described event log is also written to the card and can be displayed printed and saved using TwinComm System language The system language can be transferred using the chip card TwinCard language This...

Page 17: ...en the system recovers from energy saving mode the state of the battery system voltage is checked When the system falls below a set warning threshold an entry is made in the log and a message is displayed Press F2 to display the system voltage from the system menu Every time the system is restarted battery replacement or when the system is activated the battery voltage is measured and checked If t...

Page 18: ...d by a specially buffered real time clock and will survive even if the system receives no current for several days If a real time clock still happens to be deleted the system will be in an undefined state It must therefore be possible to set the date and time even when the system is locked Key F2 in the system menu system voltage key F2 1 0 date time system code required Further functions Protecti...

Page 19: ...rther functions All codes are saved and evaluated within the secured area Log entry of all safety relevant events Blocking times when a wrong code is entered repeatedly see code programs timer programs Configuration only possibly for unlocked systems after entering the system codes 3 6 PC Support with Configuration Set TwinComm Basically the TwinLock compact system also works without PC support bu...

Page 20: ... compact Manual Version 1 06 20 4 Operation 4 1 Display and Control Elements of the Input Equipment LC Display Background lighting Menu keys Keypad Emergency power Insertion of the chip card Chip at the bottom ...

Page 21: ...status info TwinLock compact configuration configuration code linkage configuration time delay configuration date time configuration lock I O configuration opening duress system Reset TwinLock compact import export service install new lock service motor service usercodes delete user codes programming user codes display Usercodes service central siabled configuration managercode configuration silen...

Page 22: ... i e next menu item Menu navigation to the left i e previous menu item enter Selection or confirmation clear Cancel return to previous menu item press 2 seconds return to system menu Key Pad 0 9 Numeric keys to enter timer programs etc F2 Display of the current battery voltage only possible in the system menu Code input The code is only entered via the number keys The menu keys are intended for me...

Page 23: ... For security reasons switch the system code or the master code of the individual codes immediately after Installation The default code 1 2 3 4 5 6 is pre programmed for the user no 00 system master and for the system master is 1 1 1 1 1 1 The user codes no 01 99 of the individual locks have been deactivated by the manufacturer When programming the code you must see to the new unlocking code being...

Page 24: ...ed Display of the Confirming the selected lock After the time delay has expired the release time starts Within this time window a further unlocking code must be entered After the system lock has been unlocked the system may be configured Automatic return after 3 seconds TwinLock compact open open please wait code entry 42 user no 05 Code entry code Code entry code open delay XXminXXsec Code entry ...

Page 25: ...ck Select the menu item Close see menu plan 4 2 Select a lock Lock locks With the lock closed the system cannot be re configured Automatic return after 3 seconds TwinLock compact close close Please wait close lock closed 01 close system locked close lock 01 ...

Page 26: ...enu item Status see menu plan 4 2 The status of the selected component is displayed With 2 locks in the system the version of the second lock also is on display Automatic return after 3 seconds TwinLock compact Status Info Status Info Lock closed 01 Version query SW version TS01 Lock SW version S01 ...

Page 27: ...ode entry a user entered a wrong code more than three times Attention The system has either been restarted or the power supply has been interrupted Status messages Lock can no longer be addressed at bus A Please call customer service Lock can no longer be addressed at bus B Please call customer service Final bolt position of the lock at bus A is not accessible Please call customer service Final bo...

Page 28: ... invalid entry Check entry and retry Addressed component at bus A does not respond Please call customer service Addressed component at bus B does not respond Please call customer service Error when unlocking locking a lock Please call customer service Error during communication between control unit and lock Please call customer service Status DMS XX Error invalid code invalid input failure BUS A f...

Page 29: ...des Delete a user code Display a programmed User code Activate deactivate code linkage Date Time Program unlocking delay Program silent alarm Program parallel code Activate lock I O TwinXT Write configuration and log to chip card Read configuration from chip card Import new system language Automatic locking with door switch Some of these functions and all others can be implemented by means of the ...

Page 30: ...o program the user codes When entering the code the user 00 is the master ACHTUNG The default code 1 2 3 4 5 6 is pre programmed for the master of each lock For safety reasons the master codes of the individual locks must be changed immediately When programming the code make sure that the new unlocking code is checked repeatedly while the safe is open Do not use personal data when programming unlo...

Page 31: ...pening authorization It does grant authorization to configure the system When the code is entered the user using this code is identified to be the system manager ACHTUNG The default code 1 1 1 1 1 1 is pre programmed for the manager For safety reasons the master codes of the individual locks should be changed immediately Do not use personal data The master code of lock 01 is also called the system...

Page 32: ...e new user code is saved Automatic return after 3 seconds User codes A user can reprogram his her user code autonomously Otherwise the user only has an unlocking authorization When a user code is programmed for the first time the master code has to be entered first Attention When programming the code you must see to it that the new unlocking code is checked repeatedly while the safe is open Do not...

Page 33: ...ted lock Select the user to be deleted The selected user is deleted Action completed Automatic return after 3 seconds Only the according owner of the master code can delete user codes This action is saved in the event log The function itself can only be performed at the control unit usercodes delete delete user no xx old M U code code delete please wait usercode xx deleted Code entry user no 00 de...

Page 34: ...s means that not the codes themselves are displayed but the status programmed not programmed The display of a programmed user code can only take place by entering the according master code of the lock Comment 1 line Number of programmed user codes for this lock e g progr u codes 03 Three user codes are programmed all in all 2 line Displays which user code is programmed OK programmed NOK not progra...

Page 35: ... week with menu keys Re enter date time or weekday Action completed Date Time The date time weekday can only be changed by the owner of the system code This action is saved in the event log Attention The correct setting of the date time weekday is the basis for all timer programs in the system or the event log to run properly configuration date time System Code Code System code Please wait time 10...

Page 36: ...y entering 2 codes The arrangement of the 2 codes is random The function applies to the entire system i e each lock must be unlocked with 2 codes when code linkage is activated The programming of this function can only be performed by the owner of the system code and is saved in the event log After the 4 eyes principle has been activated the system code also has to be entered in connection with a ...

Page 37: ...e time is used to safeguard the time delay If a release time was programmed e g 00 a correct unlocking code must be entered after the time delay has expired to finally open the lock The release time is set in minutes 00 99 and specifies the period during which the user can re enter the unlocking code after the time delay has expired If no release was programmed 00 the lock will open without re ent...

Page 38: ...the unlocking or locking sequence The system is in unlocked state only when all locks are open It will be in a locked state if all locks are closed Opening sequence lock 1 lock 2 system unblocked Locking sequence lock 2 lock 1 system locked The programming of this function can only be performed by the owner of the system code and is saved in the event log Factory setting No opening duress no force...

Page 39: ... a silent alarm is triggered by entering a valid unlocking code last code digit 1 see example and stored in the event log A time delay can be set 00 99 min which is only activated during the triggering of an alarm The defined release time of the programmed normal time delay is used as release time The function Silent alarm can only be performed by the owner of the system code and is saved in the e...

Page 40: ...d by means of the system code The following functionality blocking element can be achieved Input functions Locking feature contact for external release blocking of the lock Locking after bolt contact query Output functions Silent alarm relay contact for silent alarm messages Display of the lock bolt position relay contact This programming action is saved in the event log Factory setting TwinXT ina...

Page 41: ...e reset to factory defaults Unlocking delay Inactive System line TwinLock compact Battery warning limit 8 0V Code linkage 1 User Locks 0 Parallel code Inactive Forced Sequence Inactive Opening Duress Quick unlocking code user 09 Only the control unit is reset This means that all settings which are stored in the control unit are reset to factory defaults The locks are not reset during this procedur...

Page 42: ...ways 01 Select the number of locks available in the system Acknowledge with Enter To assign a serial number the system code of the lock or locks must be entered e g 1 1 1 1 1 1 The serial number is transmitted to the lock The serial number has been stored in the lock For the 2nd lock the master code of lock 2 has to be entered After all data is entered a system check is performed and the system is...

Page 43: ...losed gradually for service purposes This function can only be activated or performed by the owner of the according master code of the according lock The user has 150 seconds to the next motor step If no key is pressed the function is cancelled The gradual opening or closing of the lock bolt is only meant for service purposes and can only be performed in an unlocked system state After this functio...

Page 44: ...tem code of the new lock must be entered 1 1 1 1 1 1 The serial number is transferred to the lock Detect and initialize the lock Acknowledge the lock number Automatic return after 3 seconds Re registering replacing of locks Only the owner of the system code can re register or replace a lock This action is stored in the event log A maximum of 2 locks can be registered Service Reg lock System code C...

Page 45: ... TwinCard configuration Select Export configuration Data is written to the chip card Remove card The data can be read by means of the Configuration set TwinComm and can be processed further The data export procedure is stored in the event log TwinLock compact Import Export Systemcode Code System code Please wait Import Export Daten Export Data export Insert card Data export Configuration Write dat...

Page 46: ...nsert the TwinCard configuration Select Export configuration Data is written to the chip card Remove card The data can be read by means of the Configuration set TwinComm and can be processed further The data export procedure is stored in the event log TwinLock Import Export System code Please wait Import Export Data Export Write data Data export Remove card System code Code Data export Insert card...

Page 47: ...Evaluate the entry Select data import with the menu keys Insert the TwinCard language Select Export configuration Data is read from the chip card into the system Remove card The data import procedure is stored in the event log The new language is activated immediately after the card has been read TwinLock Import Export System code Please wait Import Export Data import Read data Data import Remove ...

Page 48: ...t system position switch which may be connected to TwinAlarm or TwinXT is ignored for one locking procedure This means that the system can still be locked properly even if the switch is damaged Note In any case the customer service should be informed Central inactive Stored System Central inactive Central inactive Yes No ...

Page 49: ...d without selecting lock 01 beforehand If lock 01 is open the condition of lock 02 is automatically queried When lock 02 is closed an unlocking code must be entered without selecting lock 02 beforehand Lock 02 unlocks Programming of the codes In all locks the same codes must be programmed for the according users e g User 08 Code Lock 1 080808 Code Lock 2 080808 Notes 1 For this functionality the e...

Page 50: ...s must be performed Connect the switch at the terminals of the bolt system position switch see assembly instructions For a two lock system the terminals of the bolt system position switch must be bridged for lock 1 and 2 Activate TwinXT via the menu or the PC software Set the forced sequence via the menu or the PC software TwinComm Setting the switching status for the locking via PC software TwinC...

Page 51: ...m alarm delay TwinXT active Automatic switching to daylight savings time Quick unlocking code Four eye principle Parallel code Lock after bolt system contact query Automatic locking with door switch Quick unlocking code System line Battery warning limit Timer Programs Alarm time delay Time delay release time Managing functions Customer data User data Menu simulator and menu wizard TwinCard Configu...

Page 52: ...rted this card must be inserted into the chip card reader After the license chip card has been read the according locking system can be selected TwinLock compact Start screen Before the chip card reader is used the serial interface to which the reader is connected must be activated The setting is done in the menu Chip card Configure Or the user is prompted to select the interface when the PC softw...

Page 53: ...om the chip card TwinCard configuration it must be inserted into the chip card reader Then push the button Read chip card To save the data to the chip card TwinCard configuration it must be inserted into the chip card reader Then push the button Write chip card ...

Page 54: ...ust be activated for the function of automatic locking with door switch Parallel code Only possible if there are 2 or 3 locks in the system Unlocking procedure During the unlocking procedure the status of lock 01 is queried first When lock 01 is closed an unlocking code must be entered without selecting lock 01 beforehand When lock 01 is open the condition of lock 02 is queried automatically When ...

Page 55: ...pt for forced sequence Forced sequence programmable i e the unlocking and locking Opening Duress sequence Unlocking Lock 01 Lock 02 Locking Lock 02 Lock 01 Battery warning limit With this function the threshold of the battery warning can be set between 6 8 V and 9 3 V Critical dropping of the supply voltage is automatically detected and the following message is displayed Switching to Daylight savi...

Page 56: ...e functions TwinXT active must be programmed TwinAlarm active not with TwinLock compact Silent alarm Activate silent alarm time delay 01 99 minutes BAS level not with TwinLock compact Arming with code card not with TwinLock compact System line The system line is displayed in the 1st line of the main menu on the display of the control unit It can be changed and set as required anytime ...

Page 57: ...g delay of 01 99 minutes can be programmed A release time of 01 15 minutes can be programmed as well during which a code entry must take place after the unlocking delay has expired Unlocking delay 00 No unlocking delay Release time 00 No code entry after unlocking delay The lock is immediately unlocked ...

Page 58: ... procedures and all code entries are logged Furthermore all configuration procedures and manipulation attempts are logged The log list can be printed on a connected printer or saved and archived in a file Use the button Update user to display the according user names after the log is being read if the users were entered ...

Page 59: ... compact Manual Version 1 06 59 7 5 User Data Management Each user of the lock can be allocated a name which is also saved in the event log The user overview can be printed or saved for administrative purposes ...

Page 60: ...rsion 1 06 60 7 6 Customer Data Management Customer data can be saved and archived for each programming This means that an individual configuration file can be created for each customer This file can be read also at a later date ...

Page 61: ...lt load approx 110 mA Dimensions 90 x 61 x 34 mm L x B x H Environment 0 50 C 75 r F Umweltklasse II nach VdS Protection class IP 30 Bus distributor TwinConnect Power Supply 12 VDC optional Current consumption For power supply operation 12 VDC Approx 9 mA Only as distributor 0 mA Dimensions 3 94 x 2 36 x 0 98 inches L x W x H Environment 32 F 122 F 75 RH Environment class II according to VdS Prote...

Page 62: ... ES GH 1 04 30 10 06 update TwinCards ES 1 05 07 12 06 Update MB 1 06 15 09 08 Update user terminal and number of users MR Subject to correction Support Hotline Carl Wittkopp GmbH Co KG Sternbergstr 5 D 42551 Velbert Tel 49 0 2051 9566 0 Fax 49 0 2051 9566 66 www cawi com INSYS Microelectronics GmbH Waffnergasse 8 D 93047 Regensburg Tel 49 0 941 58692 22 Fax 49 0 941 563471 www insys security de ...