6.20. Automatic Locking
The TwinLock system can be automatically locked using a door switch or a bolt
system position switch. The switch is connected to a TwinXT or TwinAlarm system,
depending on the system variant.
In idle state (display off), the door or bolt system switch is queried periodically.
Pressing the key will automatically lock the system.
Connection to TwinXT
The following connections and settings must be performed:
-
Connect the switch at the terminals of the bolt system position switch (see
assembly instructions). For a two lock system, the terminals of the bolt
system position switch must be bridged for lock 1 and 2.
-
Activate TwinXT (via the menu or the PC software)
-
Set the forced sequence (via the menu or the PC software TwinComm)
-
Setting the switching status for the locking (via PC software TwinComm)
Active low => when the contact is closed -> System locks
Active high => when the contact is open -> System locks
-
Setting: Automatic locking with door switch (via PC software TwinComm)
-
Optional: Combination with partial blocking time (via PC software
TwinComm)