Quick opening code
A user can be assigned the function of the quick opening code, which circumvents a
programmed time delay. The user who has stored the code with number 09 has the
quick opening code by default.
Code distribution in the TwinLock 7220 system
TwinLock
TwinLock
1 Systemcode =
1 Managercode
1 Mastercode
99 Usercodes
TwinLock
lock 1
lock 2
1 Managercode
1 Mastercode
99 Usercodes
secured area
mnemonic codes
mnemonic codes
Unlocking & Locking
The unlocking is tied to at least one code entry. This always takes place via the menu
keys (see sabotage safety). Unlocking can be prevented by several functions (timer
programs…).
Opening duress (forced sequence)
When a ‘opening duress’ is activated, the locks can only be opened in a certain order
/ sequence (lock 01, 02, ...). When locking the system, the sequence is reversed.
The system is only unlocked and accessible for configuration and service after all
locks have been opened.
Automatic lock with door switch
The system can be locked automatically using a door switch or a bolt system contact,
which is either connected to a TwinAlarm or TwinXT system, depending on the
system variant.
This function can only be configured via the PC software TwinComm.
Code linkage
For the entire system, the function ‘Four-eye code’ can be programmed. A lock can
thus only be unlocked by entering 2 user codes respectively. Programming can only
be performed by the system master. If a four-eye code has already been
programmed, the system master can perform the programming only in connection
with other users of lock 01.