background image

  

Add-On Manual 

 

 

 

INSYS GSM 4.3 easy 

 

 

 

 

Apr-09

 

Summary of Contents for GSM 4.3 easy

Page 1: ...Add On Manual INSYS GSM 4 3 easy Apr 09...

Page 2: ......

Page 3: ...ademark of Microcom Inc IBM PC AT XT are registered trademarks of International Business Machine Corporation INSYS is a registered trademark of INSYS MICROELECTRONICS GmbH Windows is a registered trad...

Page 4: ...igure Alias 11 4 2 Configure Monitoring 12 4 3 Configure Time Scheduled SMS 13 4 4 Manage Configuration Data 13 5 Functional Description 14 5 1 Definitions 14 5 1 1 Objects Instances Object Short Name...

Page 5: ...cable with 9 pin Sub D connector for the connection to the PC 1 manual INSYS GSM Additional manual INSYS GSM 4 3 easy CD ROM Optional Accessories Adapter cable D SUB 9 pin male to 9 pin male GSM anten...

Page 6: ...3 easy Both versions are referred to as INSYS GSM 4 3 easy in the further course of this manual If the INSYS GSM 4 3 easy compact differs from the INSYS GSM 4 3 easy this will be mentioned in particu...

Page 7: ...he easy status can also be changed from RUN to STOP or vice versa Monitoring of the easy object instances This message can also be performed automatically refer also to the Functional Description sect...

Page 8: ...ro tection which prevents unauthorized persons without knowledge of the exact password from remotely accessing the compact controller The LCD display needs to be in its original state before the Moell...

Page 9: ...the operation with the Moeller easy suitable connection cables are available refer to Optional Accessories in the Scope of Delivery section of this manual Alternatively the 30 cm long INSYS adapter ca...

Page 10: ...elected compact controller the speed of the serial interface is set to 4800 bps or 9600 bps When the selection is changed the complete configuration for the Moeller easy functionality is deleted as a...

Page 11: ...o 30 object instances The table is not used to en ter data but to visualize the configuration The configuration itself takes place below the table with the help of the pull down menus or the text fiel...

Page 12: ...settings are only effective when monitoring is turned on in the main window Settings from 1 to 255 seconds are possible for the monitoring interval Settings from 1 to 255 minutes are possible for the...

Page 13: ...means that the monitored object and the preferred instance can be manually selected The interval can be selected between 1 and 255 hours 4 4 Manage Configuration Data The buttons under Configuration d...

Page 14: ...register M1 can be allocated the alias waste water pump1 If an individual wants to activate the wastewater pump via mobile phone using an SMS he does not need to know that the register 1 must be used...

Page 15: ...4 3 easy Behaviour after reset or power up After a reset or a power up of the INSYS GSM 4 3 easy values of object in stances which are not within the configured target state will not trigger a fault m...

Page 16: ...o three times if necessary If there is still no reply from the easy device an SMS with the text NO SUCCESS is sent instead of the object instance value The sending of this SMS will be delayed if one o...

Page 17: ...s must have the following syntax password command CN reply CN means Callback Number password Password for remote configuration and SMS query If no password is set the separating comma is dropped also...

Page 18: ...the easy 500 700 Valid objects for the easy 800 MFD are Object Object short name Digital inputs I Extended digital inputs R Digital outputs Q Extended digital outputs S Digital registers M Analogue b...

Page 19: ...ects for the easy 500 700 are Object Object short name Valid values Digital registers M 0 or 1 Digital registers N 0 or 1 Table 4 Valid values for setting an object instance of the easy 500 700 Valid...

Page 20: ...t least the character string CN If another callback number is desired after the character string CN an additional space character and the phone number must be entered see previous example The response...

Page 21: ...INSYS GSM Due to the extended functionality of the INSYS GSM 4 3 easy there are several additional entries in the history memory Cause Detail Meaning PLC ERROR When communicating with the easy device...

Page 22: ...s serial interface now has no connection to another program but maintains the connection The program EASY SOFT can now be started and program the easy device as if it was connected to a local serial p...

Page 23: ...ased to at least 1000 ms Figure 8 Setting the timeout of the communication for easy 500 700 For the easy 800 and MFD devices the Timeout for Communication must be increased to at least 1000 ms Figure...

Page 24: ...Declaration of Conformity INSYS GSM 4 3 easy 7 Declaration of Conformity We ll send you the declaration of conformity on request 24...

Page 25: ...Possible status changes 20 Table 8 New history entries 21 8 2 List of Diagrams Figure 1 Principal connection of the INSYS GSM 4 3 easy to the Moeller easy 9 Figure 2 Software HSComm Moeller easy tm ta...

Page 26: ...26...