General Operating Instructions CombiLock
2.1
Opening and Closing
2.1.1
Opening the Electronic Lock with Code
With versions CombiLock 200 pro / RFID only:
PID
to
for one of the users 1-9,
PID
for the master.
is the opening code ex works. After failure of power supply,
battery change, for instance, and after 4 or more times of
incorrect code input, as well as after a change of keypads,
enter PID and CODE twice
.
Open the electronic lock within 10 seconds after code input by rotating the keypad
clockwise. If it is not opened within that time span, the lock will lock automatically.
Entering incorrect code four times in sequence activates a lockout / blocked time
lasting 10 seconds. Also see >Visual und Acoustic Signals<.
Electronic lock
Electronic lock
CLOSED
OPEN
2.1.2
Closing the Electronic Lock
The electronic lock engages automatically 10 seconds after opening.
In order to close it properly, r
otate the keypad into its „home position“.
Electronic lock
Electronic lock
CLOSED
OPEN
After securing the safe, always examine whether the lock is locked properly: Try
repeatedly to rotate the keypad. The lock is locked properly in case it is not
possible to turn the keypad.
2.1.3
Cancelling during Input