38
•
Press the
Capture Gate Button
or connect a gate signal to the
Capture Gate Input
to start capturing audio.
•
Capture will be activated until the maximum layer duration has been
met. If the
Capture Gate Button
is pressed while capture is activated,
or if the gate signal present at the
Capture Gate Input
is low,
recording will be stopped.
•
Once capture has deactivated, turn the
Input Level
fully
anticlockwise. This effectively turns down the
Condenser
Microphone
input signal.
•
Experiment with all granular and pitch knobs to find desired effects
and sweet spots.
Control Path:
•
Apply control voltage to any of the CV inputs of
arbhar
.