16
Spray:
The
Spray
parameter controls a random deviation of the grain
start position. The amount and location of start position deviation is
shown on the
Granular Stream
display.
•
Spray
functionality will deviate from the current
Scan
position to the
right of the layer. The
Spray
parameter is biased towards the current
Scan
position, in order to create a sense of moving through the
recording if the
Scan
position is changed.
•
The start position is set at the start of each grain and remains
unchanged for the duration of the grain.
•
If the value of the
Spray
parameter is greater than the duration
available from the
Scan
position to the end of the layer, the
Spray
parameter will extend to include the time in front of the set
Scan
position.
•
If the
Spray
parameter is set to its maximum value, the start position
for the grains will be completely random positions within the
entire layer.
Gate Output:
The
Gate Output
generates gate signals. The generation
of the gate signals are dependent on the selected
Onset Control Mode
(See the
Onset Control Modes
section for more information).
•
Output range: +5V.
•
Duty cycle: 12ms.