Variable 22 - Follower Display
-
When the MicroSpeed 196 is in the Follower
mode, the numeric display can be used as a linear tachometer (displaying actual speed
in user units), or it can be used to display the ratio that the Follower is maintaining to
the lead (i.e. the unit would read 1.000 when the follower was running at a 1:1 ratio to
the lead). When Variable 22 is selected, the alphanumeric display will read
Tach Sel.
To select between the two follower display options, enter one of the following numbers:
0000 = Linear Tachometer in User Units (Units from Variable 02)
0001 = Ratio Tachometer in User Ratio Units (Units from Variable 23)
Variable 10 - User Unit Label
-
This variable allows the user to select what the
alphanumeric display will display during normal operation -when the display is in Tach
in User Units mode. The default label is RPM
.
To program Variable 10, enter the code
that corresponds to the desired user unit label from Table 3 below.
Table 3 -
User Unit Labels
0-
R P M
1 -
FPM 2- GPM
3
-
REV/SEC 4- REV/MIN
5- REV/HR
6
-
INCH/SEC 7
-
INCH/MIN
8
-
INCH/HR
9 - FEET/SEC 10
-
FEET/MIN
11
-
FEET/HR
12
-
YARD/SEC 13
-
YARD/MIN
14
-
YARD/HR
15
-
MM/SEC 16
-
MM/MIN 17- MM/HR
18
CM/SEC 19- CM/MIN
20
-
CM/HR
21
-
MET/SEC 22
-
MET/MIN
23
-
MET/HR
24
-
OZ/SEC
25
-
OZ/MIN 26- OZ/HR
27
GAL/SEC 28- GAL/MIN 29- GAL/HR
30
-
ML/SEC 31
-
ML/MIN 32
Ml/HR
33
-
LIT/SEC 34
-
LIT/MIN
35
-
LlT/HR
36
-
HERTZ 37
-
KHERTZ 38
-
MHZ
39
-
BOT/SEC
40
-
BOT/MIN
41
-
BOT/HR
42
-
CAN/SEC 43
-
CAN/MIN
44
-
CAN/HR
45
-
LBS/SEC
46
-
LBS/MIN
47
-
LBS/HR
48
-
TURN/SEC 49
-
TURNIMI
50
-
TURN/HR
51
-
THRD/SEC
52
-
THRD/MI
53
-
THRDIHR
54
-
PART/SEC 55
-
PART/MIN
56
-
PARTSIHR
57
-
Percent% 58
-
RATIO% 65
-
Customized
15
Diagnostic 0 - Custom User Unit Labels:
If
the choices presented in Variable 10 do not provide the display that is needed, a
Custom User Unit Label can be created, for both Master and Follower modes if the
MicroSpeed 196 will be used in both modes. When programming the MicroSpeed 196
custom display, the Master/Follower input must be in the appropriate position.
Note: The Custom User Unit Label has two preprogrammed labels; one for Master
Mode, defaulted to “RPM”, and one for Follower Mode, defaulted to
“Ratio % “.
The following characters are available in the User Unit display:
ABCDEFGHIJKLMNOPQRSTUVWXYZ0123456789/*t-_and”blank.”
Use the following steps to program the desired display:
Enter Diagnostic 0 by pressing
2ND Func
and then the 0 key.
The alphanumeric display will show eight underscore characters:
-------- Press the (up arrow) or (down arrow) key to scroll through the
list of characters until the desired character for the first position is displayed.
Press the Enter key. This will lock the character into that position and move to the
next character on the eight character display. Repeat steps B and C until all eight
characters have been selected and entered.
After the rightmost character has been entered you will exit Diagnostic 0 and return
to the READY mode.
Note: Pressing 2nd Func at any time will cause an exit from Diagnostic 0 and
will return the MicroSpeed 196 to the READY mode.
5.
To display your custom user unit label during operation, set variable 10 to 65 (The
preprogrammed user unit labels in Variable 10 are still available by setting Variable
10 to the desired display number.
To clear the previously programmed label, re-enter to Diagnostic 0 (See Step 1 above
for instructions.)