Make Smoke Bridge a Controller 

1)  Press and hold Smoke Bridge set button until it beeps 

Smoke Bridge LED will start blinking green 
You will have four minutes to complete the next steps before linking mode times out

 

2)  Adjust responder to desired state

1

 

3)  Press and hold responder set button until it double-beeps 

Smoke Bridge will double-beep and its LED will stop blinking

2

 

4)  To test, first change the responder to a different state then the desired state 

5)  Test by tapping Smoke Bridge set button  

The Set button will cycle through the following notifications with a brief delay between each  

 - Smoke detected 

 - Carbon Monoxide (CO) detected 

 - Low Battery detected 

 - Error 

 - All Clear 

Smoke Bridge LED will blink red during these steps 

~15 seconds after it sends the All Clear command, it will turn solid green 

Responder will respond appropriately

 

Scenes 

Devices in a scene can each have different settings. This provides for advanced scene creation. Software 
is recommended for scene management. 
 

Example of a scene with Smoke Bridge as a Controller: 

1)  Press and hold Smoke Bridge set button until it beeps 

 

 

Smoke Bridge LED will start blinking green

 

2)  Tap Smoke Bridge set button 

 

 

Smoke Bridge LED will start double-blinking green

 

3)  For each scene member: 

a.  Adjust member to desired scene state 
b.  Press and hold Set button until it double-beeps 

4)  Tap Smoke Bridge set button  

 

 

Smoke Bridge will beep and LED will stop blinking

 

5)  To test, first change the responder to a different state then the desired state 
6)  Test by tapping Smoke Bridge set button 

The Set button will cycle through the following notifications with a brief delay between each  

 - Smoke detected 

 - Carbon Monoxide (CO) detected 

 - Low Battery detected 

 - Error 

 - All Clear 

Smoke Bridge LED will blink red during these steps 

                                            

1

 If responder is a multi-scene device such as a KeypadLinc, tap scene button you wish to control until the LED is in the desired scene state (on or off). 

2

 If either controller or responder LED continues blinking, the addition failed. Tap device’s Set button until LED stops blinking and try linking again. 

Summary of Contents for 2982-222

Page 1: ...Page 1 of 14 2982 222 Rev 1 21 2014 8 34 AM Smoke Bridge Owner s Manual 2982 222...

Page 2: ...ke Bridge a Controller of Multiple Responders 6 Remove Smoke Bridge as a Controller 6 Remove Smoke Bridge as a Controller of Multiple Responders 7 Local Control Operation and Testing 8 Adjust Local Se...

Page 3: ...Bridge is intended for installation in accordance with the National Electric Code and local regulations in the United States or the Canadian Electrical Code and local regulations in Canada Use indoor...

Page 4: ...Test pairing by pressing and holding Test button on First Alert Smoke Alarm Smoke Bridge LED will blink red until the First Alert Smoke Alarm message is complete INSTEON Setup Some products have subtl...

Page 5: ...s for advanced scene creation Software is recommended for scene management Example of a scene with Smoke Bridge as a Controller 1 Press and hold Smoke Bridge set button until it beeps Smoke Bridge LED...

Page 6: ...ed during these steps 15 seconds after it sends the All Clear command it will turn solid green Responder will respond appropriately Remove Smoke Bridge as a Controller If you no longer want Smoke Brid...

Page 7: ...g a Press and hold Set button until it double beeps 5 Tap Smoke Bridge set button Smoke Bridge will beep and LED will stop blinking 6 To test first change the responder to a different state then the d...

Page 8: ...fter All Clear then Solid Green Notes If you link to other INSTEON devices using the Set button only the Smoke Detected signal will trigger the INSTEON devices To verify Smoke Bridge puts the responde...

Page 9: ...djust settings or modify links This is typically used in commercial or installer applications Resetting Smoke Bridge to its Factory Default Settings All settings and scenes will be erased including th...

Page 10: ...on Monoxide Sensed Low Battery Sensor Malfunction All Clear Setup LED Blinks red when receiving data from First Alert OneLink Blinks green when INSTEON signals are detected Setup LED brightness Adjust...

Page 11: ...ronment Indoors Operating temperature range 32 F to 104 F 0 C to 40 C Operating humidity range 0 85 relative Storage temperature range 4 o to 158 o F 20 o to 70 o C INSTEON ID label location On backsi...

Page 12: ...devices All INSTEON devices act as INSTEON network repeaters Large appliances such as refrigerators or air conditioners may be producing electrical noise on the power line Install a power line noise...

Page 13: ...Set button to create a link to a responder links it to the Smoke Detected group only To link to the test button group you must use software or a smart device iOS or Android app Smoke Bridge is locked...

Page 14: ...ilament de tungstene afin de reduire le risqu de surchauffe et la possibilite d endommagement a d autres materiels ne pas installer pour commander une prise un appareil a moteur une lampe fluorescente...

Reviews: